© Welbilt, Inc.
J11 Connector on Control Board
Pin 1 (+)
Red
Pin 2 (-)
Black
Pin 3
Twisted Wire
Ice Thickness Probe Diagnostics
147
Indigo NXT Ice Machine Troubleshooting Tips
If the initial numbers displayed
do not
change
or initial numbers
did not
increase by 3000
during scratch test:
•
Verify the ice thickness probe connector is
properly plugged into the board ( J11 ) and
the ice thickness probe wiring is correct . If
the wiring is incorrect, replace the ITP.
10. Unplug the ITP and set a VOM to DC voltage
scale – Measure voltage across Pin 1(+) Red
Wire and Pin 2(-) Black Wire:
Premature Harvest or Freeze Up
NOTE: Please verify the ice thickness probe is plugged into the
proper position. We found that in some cases it can be plugged in
wrong, even though the plug is supposed to be a One Position plug.
Содержание Welbilt Indigo NXT QuietQube
Страница 3: ... Welbilt Inc Welbilt Inc Engineered For Ease Overview INDIGO NXT 3 ...
Страница 17: ... Welbilt Inc Welbilt Inc Engineered For Ease QuietQube CVD Installation INDIGO NXT 17 ...
Страница 32: ... Welbilt Inc Welbilt Inc Engineered For Ease EasyTouch Installation Set Up Wizard INDIGO NXT Ice Machine 32 ...
Страница 50: ... Welbilt Inc Engineered For Ease Menu Navigation Indigo NXT Ice Machines ...
Страница 54: ... Welbilt Inc Indigo NXT Menu Navigation Alert 54 Touch Screen Interface Main Menu ...
Страница 55: ... Welbilt Inc Indigo NXT Menu Navigation Alert 55 Touch Screen Interface Main Menu ...
Страница 71: ... Welbilt Inc Welbilt Inc Engineered For Ease Sequence of Operation QuietQube CVD INDIGO NXT Ice Machines 71 ...
Страница 72: ... Welbilt Inc Remote IB CVD Ice machines 72 Indigo NXT QuietQube CVD Sequence of Operation Bin Probe ...
Страница 101: ... Welbilt Inc Welbilt Inc Engineered For Ease QuietQube Remote CVD Refrigeration System INDIGO NXT Ice Machine 101 ...
Страница 114: ... Welbilt Inc Welbilt Inc Engineered For Ease Troubleshooting INDIGO NXT Ice Machine 114 ...
Страница 125: ... Welbilt Inc Review 125 Symptom 1 Symptom 2 Symptom 3 Air Water Traditional Remote QuietQube Symptom 4 ...
Страница 126: ... Welbilt Inc Welbilt Inc Engineered For Ease Troubleshooting Tips INDIGO NXT Ice Machine 126 ...
Страница 153: ... Welbilt Inc Water Level Probe Diagnostics 153 Indigo NXT Ice Machine Troubleshooting Tips ...