Section 7
Refrigeration System
Part No. 80-1100-3
7-41
Q800 SERIES
Remote
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
24 Hour Ice Production
Operating Pressures
Q1000 SERIES
Self-Contained Air-Cooled
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
24 Hour Ice Production
Operating Pressures
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
-20/-28.9 to
70/21.1
9.5-11.0
10.6-12.2
11.6-13.4
1-2.5
80/26.7
9.7-11.1
10.8-12.4
11.9-13.6
90/32.2
9.8-11.3
11.0-12.6
12.1-13.8
100/37.8
10.6-12.2
11.9-13.6
13.2-15.1
110/43.3
11.9-13.6
13.4-15.4
14.7-16.9
Times in minutes
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
-20/-28.9 to
70/21.1
750
685
630
80/26.7
740
675
620
90/32.2
730
665
610
100/37.8
685
620
565
110/43.3
620
555
510
Based on average ice slab weight of 5.75- 6.50lb
Regular cube derate is 7%
Ratings with JC0895 condenser, dice or half dice cubes
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharg
e
Pressure
PSIG
Suction
Pressure
PSIG
Discharg
e
Pressure
PSIG
Suction
Pressure
PSIG
-20/-28.9 to
50/10.0
220-250
30-22
180-200
65-90
70/21.1
225-250
32-22
190-200
70-90
80/26.7
240-260
33-22
190-205
70-90
90/32.2
255-265
34-22
195-205
70-90
100/37.8
275-295
38-24
200-210
70-90
110/43.3
280-320
40-26
200-225
75-100
Suction pressure drops gradually throughout the freeze cycle
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
9.9-10.6
10.6-11.4
11.3-12.2
1-2.5
80/26.7
10.2-11.0
11.2-12.0
11.9-12.8
90/32.2
10.9-11.7
11.9-12.8
12.8-13.7
100/37.8
12.1-13.0
13.2-14.1
14.2-15.2
Times in minutes
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
980
920
870
80/26.7
950
880
830
90/32.2
900
830
780
100/37.8
820
760
710
Based on average ice slab weight of 7.75 - 8.25lb
Regular cube derate is 7%
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharg
e
Pressure
PSIG
Suction
Pressure
PSIG
Discharg
e
Pressure
PSIG
Suction
Pressure
PSIG
50/10.0
220-280
38-18
135-180
65-90
70/21.1
220-280
40-18
140-180
70-90
80/26.7
225-280
42-20
140-180
70-95
90/32.2
260-295
42-22
150-200
80-100
100/37.8
300-330
42-24
210-225
80-100
110/43.3
320-360
44-24
210-240
85-120
Suction pressure drops gradually throughout the freeze cycle
Содержание QD0202A
Страница 3: ......
Страница 14: ...General Information Section 1 1 4 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 34: ...Installation Instructions Section 2 2 20 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 50: ...Maintenance Section 3 3 16 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 93: ...Section 6 Electrical System Part No 80 1100 3 6 37 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 112: ...Electrical System Section 6 6 56 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 135: ...Section 7 Refrigeration System Part No 80 1100 3 7 23 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 168: ...Refrigeration System Section 7 7 56 Part No 80 1100 3 Figure 7 18 Using Pinch Off Tool SV1406 ...
Страница 174: ...Refrigeration System Section 7 7 62 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 175: ...Section 7 Refrigeration System Part No 80 1100 3 7 63 THIS PAGE INTENTIONALLY LEFT BLANK ...