Section 7
Refrigeration System
Part No. 80-1100-3
7-43
Q1300 SERIES
Self-Contained Air-Cooled
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
24 Hour Ice Production
Operating Pressures
Q1300 SERIES
Self-Contained Water-Cooled
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
24 Hour Ice Production
Operating Pressures
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
9.4-10.5
9.9-11.1
10.9-12.2
1-2.5
80/26.7
9.9-11.1
10.6-11.8
11.6-12.9
90/32.2
11.0-12.3
11.5-12.8
12.8-14.2
100/37.8
12.3-13.7
13.2-14.7
14.7-16.3
Times in minutes
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
1320
1260
1160
80/26.7
1260
1190
1100
90/32.2
1150
1110
1010
100/37.8
1040
980
890
Based on average ice slab weight of 10.0- 11.0 lb
Regular cube derate is 7%
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharg
e
Pressure
PSIG
Suction
Pressure
PSIG
Discharg
e
Pressure
PSIG
Suction
Pressure
PSIG
50/10.0
220-280
40-20
140-170
65-80
70/21.1
220-280
40-20
145-170
70-80
80/26.7
220-280
42-22
150-185
70-80
90/32.2
245-300
48-26
160-190
70-85
100/37.8
275-330
50-26
160-210
70-90
110/43.3
280-360
52-28
165-225
75-100
Suction pressure drops gradually throughout the freeze cycle
Air Temp.
Around Ice
Machine
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
9.0-10.1
9.8-10.9
11.4-12.6
1-2.5
80/26.7
9.1-10.1
9.8-11.0
11.6-12.9
90/32.2
9.2-10.3
10.0-11.2
12.0-13.3
100/37.8
9.4-10.5
10.1-11.3
12.2-13.6
Times in minutes
Air Temp.
Around Ice
Machine
°F/°C
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
1370
1280
1120
80/26.7
1360
1270
1100
90/32.2
1340
1250
1070
100/37.8
1320
1240
1050
Based on average ice slab weight of 10.0 - 11.0 lb
Regular cube derate is 7%
Condenser
Water
Consumption
90/32.2 Air Temperature
Around Ice Machine
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
Gal/24 hours
1150
2220
7400
Water regulating valve set to maintain 240 PSIG discharge pressure
Air Temp.
Around Ice
Machine
°F/°C
Freeze Cycle
Harvest Cycle
Discharg
e
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
50/10.0
235-245
40-18
150-180
70-80
70/21.1
235-245
40-18
150-180
70-80
80/26.7
235-245
40-20
150-180
70-80
90/32.2
235-250
42-20
150-180
70-80
100/37.8
235-255
44-20
150-180
70-80
110/43.3
240-265
46-20
150-180
70-80
Suction pressure drops gradually throughout the freeze cycle
Содержание QD0202A
Страница 3: ......
Страница 14: ...General Information Section 1 1 4 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 34: ...Installation Instructions Section 2 2 20 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 50: ...Maintenance Section 3 3 16 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 93: ...Section 6 Electrical System Part No 80 1100 3 6 37 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 112: ...Electrical System Section 6 6 56 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 135: ...Section 7 Refrigeration System Part No 80 1100 3 7 23 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 168: ...Refrigeration System Section 7 7 56 Part No 80 1100 3 Figure 7 18 Using Pinch Off Tool SV1406 ...
Страница 174: ...Refrigeration System Section 7 7 62 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 175: ...Section 7 Refrigeration System Part No 80 1100 3 7 63 THIS PAGE INTENTIONALLY LEFT BLANK ...