72
Part Number STH042 3/14
Refrigeration System
•
Non-Manitowoc components
•
Improper refrigerant charge
•
Defective compressor
•
TXV starving or flooding (check bulb mounting)
•
Non-condensable in refrigeration system
•
Plugged or restricted high side refrigerant lines or
component
•
Defective harvest valve