Part Number STH042 3/14
61
Ice Machine Cycles Into Harvest Before
Water loses Contact with the Harvest
Float Switch
Step 1
Disconnect power to the ice machine, remove
the electrical panel to allow viewing of the control
board lights and pull the wire connector for the harvest
float switch through the bulkhead and disconnect.
WIRE CONNECTORS ARE LOCATED BEHIND BULKHEAD
PULL THROUGH GROMMET TO DISCONNECT
ICE THICKNESS FLOAT
SWITCH & BRACKET
HARVEST FLOAT
SWITCH & BRACKET