Part Number Preliminary 6/11
237
Diagnostics
SYMPTOMS
Bin Switch Fails Open
•
The ice machine will not start an ice making cycle
and the display indicates “Curtain Open”.
•
The ice machine will run in the clean cycle.
Bin Switch Fails Closed
•
When running a “Long Harvest” alert is displayed
and safety limit 2 indicated.
•
May be off on a safety limit 2.
•
The harvest cycle continues after ice opens and
closes the ice damper (harvest cycle is 3.5
minutes for single evaporators and 7 minutes for
multiple evaporator models).
DIAGNOSTICS
1. Verify bin switch, damper and damper magnet are
in place.
•
Press the Menu button.
•
Scroll down to Service and press right arrow.
•
Scroll down to Diagnostics and press right arrow
•
Scroll down to Inputs and press right arrow to
display curtain switch readings (Curt SW1, Curt
SW2, etc).
2. Open and close the ice damper(s) repeatedly
while observing the display and control board
lights.
A. Curtain switch cycles open/closed and
control board light energizes/de-energizes -
Bin switch is operating normally
B. Curtain switch remains closed and control
board light remains on - Replace bin switch
C. Curtain switch remains open and control
board light remains off - Go to next step
Содержание ICVD3095
Страница 2: ......
Страница 12: ...12 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Страница 25: ...Part Number Preliminary 6 11 25 This Page Intentionally Left Blank ...
Страница 26: ...26 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Страница 36: ...36 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Страница 72: ...72 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Страница 101: ...Part Number Preliminary 6 11 101 This Page Intentionally Left Blank ...
Страница 132: ...132 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Страница 137: ...Part Number Preliminary 6 11 137 This Page Intentionally Left Blank ...
Страница 138: ...138 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Страница 187: ...Part Number Preliminary 6 11 187 This Page Intentionally Left Blank ...
Страница 188: ...188 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Страница 225: ...Part Number Preliminary 6 11 225 This Page Intentionally Left Blank ...
Страница 226: ...226 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Страница 262: ...262 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Страница 283: ...Part Number Preliminary 6 11 283 ACCESS REMOTE RECOVERY EVACUATION CONNECTIONS ...
Страница 291: ...Part Number Preliminary 6 11 291 This Page Intentionally Left Blank ...
Страница 298: ...298 Part Number Preliminary 6 11 USING PINCH OFF TOOL ...
Страница 303: ...Part Number Preliminary 6 11 303 This Page Intentionally Left Blank ...
Страница 304: ...304 Part Number Preliminary 6 11 ...
Страница 305: ...Part Number Preliminary 6 11 305 This Page Intentionally Left Blank ...
Страница 306: ...306 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Страница 336: ...336 Part Number Preliminary 6 11 I0300 I0320 I0450 I0500 I0520 Self Contained Air Water cooled 1 Ph ...
Страница 337: ...Part Number Preliminary 6 11 337 I0500 Remote Air cooled 1Ph ...
Страница 338: ...338 Part Number Preliminary 6 11 I0600 I0850 I1000 I1200 Self Contained Air Water cooled 1 3 Ph ...
Страница 339: ...Part Number Preliminary 6 11 339 I0600 I0850 I1000 Remote Condenser Air cooled 1 3 Ph ...
Страница 340: ...340 Part Number Preliminary 6 11 I0670C I0870C I1070C I1270C QuietQube Remote Air cooled 1 3 Ph ...
Страница 341: ...Part Number Preliminary 6 11 341 IB0690C IB0890C IB1090C QuietQube Remote Air cooled 1 3 Ph ...
Страница 342: ...342 Part Number Preliminary 6 11 I1400 I1800 Self Contained Air Water cooled 1 3 Ph ...
Страница 343: ...Part Number Preliminary 6 11 343 I1400 I1800 Remote Air cooled 1 3 Ph ...
Страница 349: ......