136
Part Number Preliminary 6/11
SAFETY LIMIT #2
Single Evaporator Models - Harvest time exceeds 3.5
minutes for 500 consecutive harvest cycles
Multiple Evaporator Models - Harvest time exceeds 7
minutes for 500 consecutive harvest cycles
Possible Cause Checklist
Improper Installation
•
Refer to “Installation/Visual Inspection Checklist”
page 162
Water System
•
Water area (evaporator) dirty
•
Dirty/defective water dump valve
•
Vent tube not installed on water outlet drain
•
Water freezing behind evaporator
•
Plastic extrusions and gaskets not securely
mounted to the evaporator
•
Low water pressure (20 psig min.)
•
Loss of water from sump area
•
Clogged water distribution tube
•
Dirty/defective water fill valve
•
Defective water pump
Electrical System
•
Ice thickness probe out of adjustment
•
Ice thickness probe dirty
•
Bin switch closed/defective
•
Premature harvest
•
I3300W Only - Harvest pressure solenoid valve
not energizing
Refrigeration System
•
Non-Manitowoc components
•
Improper refrigerant charge
•
Defective head pressure control valve
•
Defective harvest valve
•
TXV flooding (check bulb mounting)
•
Defective fan cycling control
•
Water cooled only - Water inlet valve is incorrectly
adjusted or will not close during harvest cycle.
•
I3300W Only - Harvest pressure solenoid valve
not energizing.
Содержание ICVD3095
Страница 2: ......
Страница 12: ...12 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Страница 25: ...Part Number Preliminary 6 11 25 This Page Intentionally Left Blank ...
Страница 26: ...26 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Страница 36: ...36 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Страница 72: ...72 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Страница 101: ...Part Number Preliminary 6 11 101 This Page Intentionally Left Blank ...
Страница 132: ...132 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Страница 137: ...Part Number Preliminary 6 11 137 This Page Intentionally Left Blank ...
Страница 138: ...138 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Страница 187: ...Part Number Preliminary 6 11 187 This Page Intentionally Left Blank ...
Страница 188: ...188 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Страница 225: ...Part Number Preliminary 6 11 225 This Page Intentionally Left Blank ...
Страница 226: ...226 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Страница 262: ...262 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Страница 283: ...Part Number Preliminary 6 11 283 ACCESS REMOTE RECOVERY EVACUATION CONNECTIONS ...
Страница 291: ...Part Number Preliminary 6 11 291 This Page Intentionally Left Blank ...
Страница 298: ...298 Part Number Preliminary 6 11 USING PINCH OFF TOOL ...
Страница 303: ...Part Number Preliminary 6 11 303 This Page Intentionally Left Blank ...
Страница 304: ...304 Part Number Preliminary 6 11 ...
Страница 305: ...Part Number Preliminary 6 11 305 This Page Intentionally Left Blank ...
Страница 306: ...306 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Страница 336: ...336 Part Number Preliminary 6 11 I0300 I0320 I0450 I0500 I0520 Self Contained Air Water cooled 1 Ph ...
Страница 337: ...Part Number Preliminary 6 11 337 I0500 Remote Air cooled 1Ph ...
Страница 338: ...338 Part Number Preliminary 6 11 I0600 I0850 I1000 I1200 Self Contained Air Water cooled 1 3 Ph ...
Страница 339: ...Part Number Preliminary 6 11 339 I0600 I0850 I1000 Remote Condenser Air cooled 1 3 Ph ...
Страница 340: ...340 Part Number Preliminary 6 11 I0670C I0870C I1070C I1270C QuietQube Remote Air cooled 1 3 Ph ...
Страница 341: ...Part Number Preliminary 6 11 341 IB0690C IB0890C IB1090C QuietQube Remote Air cooled 1 3 Ph ...
Страница 342: ...342 Part Number Preliminary 6 11 I1400 I1800 Self Contained Air Water cooled 1 3 Ph ...
Страница 343: ...Part Number Preliminary 6 11 343 I1400 I1800 Remote Air cooled 1 3 Ph ...
Страница 349: ......