D. Remove ice thickness probe
• Compress the hinge pin on the top of the ice thickness
probe.
• Pivot the ice thickness probe to disengage one pin
then the other. The ice thickness probe can be cleaned
at this point without complete removal. If complete
removal is desired, disconnect the ice thickness control
wiring from the control board.
E. Remove ice dampers
• Grasp ice damper and apply pressure toward the back
mounting bracket.
• Apply pressure to the front mounting bracket with
thumb.
• Pull ice damper download when the front ice damper
pin disengages.
F. Remove the water pump assembly
• Disconnect the vinyl distribution tube from the water
pump.
• Disconnect the water pump and water level probe
electrical connections.
• After the wires are disconnected, remove the two
thumbscrews and lift the water pump assembly out of
the ice machine.
• Depress tabs, lift and remove water pump. Do not
immerse the water pump motor in cleaner or sanitizer
solutions.
• Remove the water level probe from the assembly
housing.