PARTS REMOVAL FOR CLEANING/SANITIZING
Single Evaporator Ice Machines
B
C
D
E
A
A. Remove the water curtain
• Gently flex the curtain in the center and remove it
from the right side.
• Slide the left pin out.
B. Remove the water trough
• Depress tabs on right and left side of the water trough.
• Allow front of water trough to drop as you pull forward
to disengage the rear pins.
C. Remove the water level probe
• Pull the water level probe straight down to disengage.
• Lower the water level probe until the wiring connector
is visible.
• Disconnect the wire lead from the water level probe.
• Remove the water level probe from the ice machine.