Part Number 4520898 Rev 7 11/15 33
ELECTRICAL SPECIFICATIONS
Model
Power
Voltage (50/60 Hz)
Plug
BH/IN 2500
2500W 12A
208V 1Φ
2500W 11A
240V 1Φ
2500W 12A
230V 1Φ
EU1-16P
SH/IN 2500
2500W 12A
208V 1Φ
2500W 11A
240V 1Φ
2500W 12A
230V 1Φ
EU1-16P
SH/IN 3500
3500W 16A
208V 1Φ
3500W 14A
240V 1Φ
3500W 15A
230V 1Φ
EU1-16P
SH/IN 5000
5000W 14A
208V 3Φ
L
5000W 8A
400V 3Φ
EU 5-Pole
5000W 7A
440V 3Φ
Plug not
included
SH/WO/IN
3500
3500W 16A
208V 1Φ
3500W 14A
240V 1Φ
3500W 15A
230V 1Φ
EU1-16P
SH/WO/IN
5000
5000W 14A
208V 3Φ
L
5000W 8A
400V 3Φ
EU 5-Pole
5000W 7A
440V 3Φ
Plug not
included
SH/WO/IN
8000
8000W 12A
400V 3Φ
EU 5-Pole
Notice
440V Appliance: The electrician must equip the
appliance with a main power supply plug in compliance
with all applicable national and local regulations.
ELECTRICAL CABLES
• Power supply cable and plug, 1.8-meter [6-foot] long
(exception 440V appliance).
• Control unit cable with an Amphenol plug, 1-meter [3-
foot] long.
WEIGHTS
Model
Net Weight
kg
lb
BH/IN 2500
7
15.4
SH/IN 2500
9
19.8
SH/IN 3500
9
19.8
SH/IN 5000
11
24.2
SH/WO/IN 3500
9
19.8
SH/WO/IN 5000
10
22.0
SH/WO/IN 8000
10
22.0
OPERATING CONDITIONS
For the appliance to function properly, the following
conditions must be maintained.
Maximum Tolerance of
Nominal Supply Voltage
+6 /-10 %
Supply frequency
50/60 Hz
Liquid Ingress Protection
Level
IPX0 (Not Protected)
NOTE: Protection by customer is
required.
Minimal Diameter of
Induction Pan
(BH/IN, SH/IN units)
12cm [5”]
Maximum Ambient
Temperature
In Storage,
-20°C to +70°C [-4°F to +158°F]
In Operation,
+5°C to +40°C [+41°F to +104°F]
Maximum Relative Air
Humidity
In Storage, 10% to 90%
In Operation, 30% to 90%
Exhaust Clearance
Minimum 40mm [1.57”]
Opening on cabinet for
exhaust
Total sum of minimum
194
square centimeters [30 square
inches] per single built-in
appliance.
Maximum Fan Air Flow
220m
3
per hour [129.49 cfm]
Minimum opening for fresh air
supply required: total sum of
11300mm
2
[17.52 square inches].
Содержание BH/IN 2500