22
Part Number 4520898 Rev 7 11/15
Flush-Mount Installation On Stone Countertop
EXAMPLE 4
(i) A stone block is glued to the stone countertop. (ii)
A chamfer is necessary to provide adequate exhaust
clearance. (iii) Silicone sealant shown.
i
ii
iii
EXAMPLE 5
(i) A support bracket (minimum 2mm [14 gauge]) is
stud-mounted onto the underside of the countertop.
The bracket is bended at both ends to provide the
required recess height and to reinforce the countertop.
(ii) Silicone sealant shown.
i
ii
EXAMPLE 6
(i) A support bracket (typical 1mm [18 gauge]) is
mounted onto the cut-out area of the countertop. (ii)
Additional reinforcement might be needed (typical
minimum 2mm [14-gauge] bracket used). (iii) Silicone
sealant shown.
i
ii
iii
Top-Mount Installation On Stone Countertop
EXAMPLE 7
(i) A support bracket (minimum 2mm [14-gauge]) is
stud-mounted onto the countertop. The bracket is
bended at both ends to provide the required air gap
(below, item ii) and to reinforce the countertop. (iii)
Silicone sealant shown.
i
ii
iii
EXAMPLE 8
(i) A chamfer is made in the stone countertop
to provide the required air gap. (ii) Additional
reinforcement might be needed (typical minimum 2mm
[14-gauge] bracket used). (iii) Silicone sealant shown.
i
iii
ii
Содержание BH/IN 2500