38
Part Number 4520898 Rev 7 11/15
CONNECTING THE COMPONENTS
Read and understand all installation safety
instructions regarding Electrical and Personal
Protection.
Notice
440V Appliance: The electrician must equip the
appliance with a main power supply plug in compliance
with all applicable national and local regulations.
NOTE: Operating Conditions:
Maximum Tolerance of
Nominal Supply Voltage
+6 /-10 %
Supply frequency
50/60 Hz
To connect the components:
1.
n
Warning
Ensure the control knobs are in the 0 (OFF) position
BEFORE connecting the appliance to the electrical
supply.
ON-Position
Any position
other
than “0” is
pointing to
the indicator
lamp. The
lamp is on.
OFF-Position
“0” is pointing
to the
indicator
lamp. The
lamp is off.
2. Remove all objects from the glass-top and examine the
glass.
,
Caution
Do not continue if the glass-top is cracked, chipped
or damaged in any other way. Contact an authorized
service agency for assistance.
3. Connect the Amphenol plug (below,
1
) from the
control unit to the cooktop/wok assembly:
•
The mating connectors are keyed such that the
plug can be connected in only one orientation.
•
Align the connectors and plug in the Amphenol
plug. Then rotate the locking nut on the plug
clockwise. Stop when the connectors are locked.
4. Connect the power plug (below,
2
) to power socket.
2
1
5.
Never tie together the control unit cable and the
power supply cable.
Notice
To avoid radio frequency interference, route
separately the control unit cable from the power
supply cable.
6. NOTE: In some installation methods, it is required by
electrical standards to bond the appliance to the metal
chassis that it is mounted in. We recommend always
adding a bonding conductor. To identify the bond
connection, see the dimensional drawings.
7. Test the appliance. See instructions in Function Test on
Содержание BH/IN 2500