Part Number 4520898 Rev 7 11/15 21
Countertop Support Requirements
,
Caution
Consultants, fabricators and designers must consult their
countertop suppliers when designing an appropriate
support structure and clearance for the countertop and
the installation.
DANGER
Risk of Fire or Shock or Equipment Failure
All minimum clearances must be maintained. Air intake
vents and exhaust vents must not be blocked or be
restricted by the installation.
The induction appliance can be installed either top-mount
or flush-mount. This section provides examples of possible
support structures for your consideration.
For cut-out dimensions, see Specifications on page 23.
Flush-Mount Installation On A Typical Countertop
EXAMPLE 1
(i) A typical countertop of 2 to 3 mm thick. (ii) A
support bracket is stud-mounted (or welded) onto the
underside of the countertop. The bracket is bended to
provide the required recess height. (iii) Silicone sealant
shown.
i
ii
iii
EXAMPLE 2
(i) A countertop is machined to provide a recess flange.
Typically, a 1mm [18-gauge] thick countertop is used
for this type of application. (ii) Silicone sealant shown.
i
ii
EXAMPLE 3
(i) A plate steel countertop is thick enough for the
required recess height. (ii) A flat plate is attached to
the countertop as the installation support. (iii) Silicone
sealant shown.
i
ii
iii