Reference
Only
Manitowoc
Published 05-16-17, Control # 233-03
2-9
999 SERVICE/MAINTENANCE MANUAL
HYDRAULIC SYSTEM
2
ORS Connection
•
Lubricate and install O-ring in adapter groove
(
•
Lubricate threads.
•
Tighten nut to torque value given in
.
Table 2-4. ORS Assembly Torque
Table 2-5. ORS Leakage
Nut Size
inch across
flats
Fitting
Size
Torque
In-Lb
N•m
5/8
-04
120 – 145
14 – 16
13/16
-06
203 – 245
23 – 28
15/16
-08
380 – 470
43 – 53
1-1/8
-10
550 – 680
62 – 77
1-3/8
-12
763 – 945
86 – 107
1-5/8
-16
1110 – 1260
125 – 142
1-7/8
-20
1500 – 1680
170 – 190
Nut
Adapter
O-Ring
FIGURE 2-5
S105
Causes
Cures
Nut Loose.
Tighten to proper torque.
O-ring cut.
Replace.
O-ring wrong size.
Replace with proper size.
Sealing surfaces gouged
or scratched.
Repair if possible or replace
damaged parts.
Sealing surfaces dirty.
Clean and lubricate.