Test 2– Checking Resistance at Engine Temperature Sender
Set digital multi-meter to test resistance. Make required
connections to test lead adapter at the meter. Connect
negative lead to a grounded component on the crane and
the positive lead to engine temperature sender wire
terminal. With engine cold, check for a resistance of
approximately 0.70 ohms.
Item
Description
1
Temperature Sender
1
P1589