Test 17 – Checking Pump Charge Pressure
Component charge systems can be checked at the desired
system diagnostic gauge coupler at pressure sender. To
check pump charge pressure:
•
Install a 0 – 600 psi (0 – 42 bar) gauge at the desired
system diagnostic gauge coupler at pressure sender.
•
Start system and record charge pressure at engine idle
speed.
•
No hydraulic systems should be enabled.
•
A reading of 350 psi (24 bar) is system charge pressure.
•
A reading of less than 350 psi (24 bar) indicates a charge
pressure relief adjustment is necessary. See Test 18.
Item
Description
1
Pressure Sender
2
Charge Pressure Test Port
3
Text Gauge
3
P1599
2
1