Reference
Only
Manitowoc
Published 05-16-17, Control # 233-03
3-21
999 SERVICE/MAINTENANCE MANUAL
ELECTRIC SYSTEM
3
Controller Board Identification
Board
(Signal Type)
Pin
Wire
Description
Test Voltage
(DC unless otherwise specified)
CPU J1-01
A-01
87F
10 VDC Regulated Bus
10 Volts
CPU J3-49 (AI)
A-20
83Q
Right Track Hydraulic Pressure
1.2 Volts at 300 psi; 1 Volt at 0 psi
CPU J3-50 (AI)
A-28
42
Hydraulic Fluid Temperature Switch
12 Volts Nominal
CPU J3-51 (AI)
A-21
81QA
Accessory System Hydraulic Pressure
1.2 Volts at 300 psi; 1 Volt at 0 psi
CPU J3-52 (AI)
A-29
84Q
Left Track Hydraulic Pressure
1.2 Volts at 300 psi; 1 Volt at 0 psi
CPU J3-53 (AI)
A-22
80QS
Front Drum Hydraulic Pressure
1.2 Volts at 300 psi; 1 Volt at 0 psi
CPU J3-54 (AI)
A-30
90E
Backhitch Load Sensor
1.5 Volts at No Load
9.5 Volts at Maximum Load
CPU J3-55 (AI)
A-23
81QS
Rear Drum Hydraulic Pressure
1.2 Volts at 300 psi; 1 Volt at 0 psi
CPU J3-56 (AI)
A-34
Spare
CPU J3-57 (AI)
A-24
82QS
Boom Hoist Drum Hydraulic Pressure
1.2 Volts at 300 psi; 1 Volt at 0 psi
CPU J3-58 (AI)
A-35
88MA
Mast Angle Sensor
5 VDC Mast at Vertical
CPU J3-59 (AI)
A-25
85QR
Swing Right Hydraulic Pressure
1.2 Volts at 300 psi; 1 Volt at 0 psi
CPU J3-60 (AI)
A-36
Spare
CPU J3-61 (AI)
A-26
85QL
Swing Left Hydraulic Pressure
1.2 Volts at 300 psi; 1 Volt at 0 psi
CPU J3-62 (AI)
A-37
89D4
Hydraulic Suction Switch
12 Volts Nominal
CPU J3-63 (AI)
A-27
86QS
Auxiliary Drum Hydraulic Pressure
1.2 Volts at 300 psi; 1 Volt at 0 psi
CPU J3-64 (AI)
A-02
Spare
CPU J4-01 (COMM)
D-17
36
RS232 (Transmit to Laptop)
CPU J4-02 (COMM)
D-16
37
RS232 (Receive from Laptop)
CPU J4-03-04 (COMM)
D-18
Spare
CPU J4-05 (COMM)
D-19
31
RS232 To Display – White
CPU J4-07-08 (COMM)
D-20
30
RS232 To Display – Black (Ground)
0 Volts
CPU J4-09 (COMM)
D-22
34
RS232 Transmit to LMI
CPU J4-10 (COMM)
D-21
35
RS232 Receive from LMI
I/O 1 J5-50 (AI)
A-03
80P
Front Drum Handle
0 Volts Neutral; 1.4 to 5 Volts Lower;
5 to 8.6 Volts Raise
I/O 1 J5-52 (AI)
A-04
81P
Rear Drum Handle
0 Volts Neutral; 1.4 to 5 Volts Lower;
5 to 8.6 Volts Raise
I/O 1 J5-54 (AI)
A-05
82P
Boom Hoist Drum Handle
0 Volts Neutral; 1.4 to 5 Volts Lower;
5 to 8.6 Volts Raise
I/O 1 J5-56 (AI)
A-06
83P
Right Track Handle
0 Volts Neutral; 1.4 to 5 Volts Reverse;
5 to 8.6 Volts Forward
I/O 1 J5-58 (AI)
A-07
84P
Left Track Handle
0 Volts Neutral; 1.4 to 5 Volts Reverse;
5 to 8.6 Volts Forward
I/O 1 J5-60 (AI)
A-08
85P
Swing Handle
0 Volts Neutral; 1.7 to 5 Volts Right;
5 to 8.3 Volts Left
I/O 1 J5-62 (AI)
A-09
86P
Auxiliary Drum Handle
0 Volts Neutral; 1.4 to 5 Volts Lower;
5 to 8.6 Volts Raise
I/O 1 J5-64 (AI)
A-10
101
Remote Input Node Communication
I/O 1 J6-01 (DI)
D-01
80MA
Front Drum Flange Encoder CH A
7.5 Volts or 0 Volts Not Moving
3.5 Volts Moving
I/O 1 J6-02 (DI)
D-02
80MB
Front Drum Flange Encoder CH B
7.5 Volts or 0 Volts Not Moving
3.5 Volts Moving
I/O 1 J6-03 (DI)
D-03
81MA
Rear Drum Flange Encoder CH A
7.5 Volts or 0 Volts Not Moving
3.5 Volts Moving
Содержание 999
Страница 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc 999 ...
Страница 2: ...R e f e r e n c e O n l y ...
Страница 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Страница 173: ...R e f e r e n c e O n l y Manitowoc Published 05 16 17 Control 233 03 4 19 999 SERVICE MAINTENANCE MANUAL BOOM 4 ...
Страница 174: ...R e f e r e n c e O n l y BOOM 999 SERVICE MAINTENANCE MANUAL 4 20 Published 05 16 17 Control 233 03 ...
Страница 297: ...R e f e r e n c e O n l y ...
Страница 298: ...R e f e r e n c e O n l y ...