999 SERVICE/MAINTENANCE MANUAL
INTRODUCTION
1
Electrical Power to 999 Operator Cab
Voltage is available to operate dome light switch (1), horn
switch (2), when key-operated engine switch (3) is in stop
position. After key-operated engine switch is placed in run
position, power is available to the EPIC programmable
computer, air conditioning relay (ACR), power relay (K1),
engine control module relay (ECM), and start relay (MS1).
When power relay K1 is enabled, power is available to
operate crane controls and accessory controls (see
Electrical Schematic drawings in Section 3).
FIGURE 1-5
K1
HORN
6A
20A
5H
45
5A
TRANSIENT SUPPRESSOR
5A
0
0
24 VDC
STARTER
MOTOR
6A
6A1
SS
MS1
SOL
5A
6B
ALT
12 VDC
DOME LIGHT
5A
5B
90 AMP
5
CB1
5
SOLENOID
6A1
ES
SS
M
STARTER
6C
CB2
30A
6
70A
15 AMP
CB3
5A
5C
15 AMP
CB4
K3
W
ENGINE
10A
5D
5A
F15
STOP
F14
STOP
TO OTHER CAB
CONTROLS
0
K1
CAB POWER
ETHER VALVE
ER
3
ENGINE
RUN
START
7
K3
ACR
ENGINE
MODULE
8ECM
5C
CONTROL
MS1
8
999CSM1-104
Содержание 999
Страница 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc 999 ...
Страница 2: ...R e f e r e n c e O n l y ...
Страница 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Страница 173: ...R e f e r e n c e O n l y Manitowoc Published 05 16 17 Control 233 03 4 19 999 SERVICE MAINTENANCE MANUAL BOOM 4 ...
Страница 174: ...R e f e r e n c e O n l y BOOM 999 SERVICE MAINTENANCE MANUAL 4 20 Published 05 16 17 Control 233 03 ...
Страница 297: ...R e f e r e n c e O n l y ...
Страница 298: ...R e f e r e n c e O n l y ...