Gantry Cylinder Extend Solenoid
C-32
43
12 Volts Nominal
I/O 2 J8-31-32 (DO)
Gantry Cylinder Retract Solenoid
C-33
44
12 Volts Nominal
I/O 2 J8-33-34 (DO)
Gantry Lower Switch
B-28
89B5
12 Volts Nominal
I/O 2 J8-20 (DI)
Gantry Raise Switch
B-27
89A5
12 Volts Nominal
I/O 2 J8-19 (DI)
Gantry Up Limit
B-22
89W3
12 Volts Nominal
I/O 2 J8-14 (DI)
High Speed Travel Solenoid
D-31
84R
12 Volts Nominal
I/O 3 J10-31-32 (DO)
High Speed Travel Switch
B-35
89L1
12 Volts Nominal
I/O 3 J10-13 (DI)
Hydraulic Fluid Level
B-16
89R3
12 Volts Nominal
I/O 2 J8-08 (DI)
Hydraulic Fluid Temperature Switch
A-28
42
12 Volts Nominal
CPU J3-50 (AI)
Hydraulic Suction Switch
A-37
89D4
12 Volts Nominal
CPU J3-62 (AI)
Left Track Handle
A-07
84P
0 Volts Neutral; 1.4 to 5 Volts Reverse;
5 to 8.6 Volts Forward
I/O 1 J5-58 (AI)
Left Track Hydraulic Pressure
A-29
84Q
1.2 Volts at 300 psi; 1 Volt at 0 psi
CPU J3-52 (AI)
Left Track Pedal
A-13
84PF
0 Volts Neutral; 1.4 to 5 Volts Reverse;
5 to 8.6 Volts Forward
I/O 2 J7-52 (AI)
Left Track Pump Control (Servo Driver 5)
C-23
84A
0 to 2.8
±
10% (110 mA) Volts Reverse;
0 to -2. 8
±
10% (-110 mA) Volts Forward
I/O 3 J10-41 (AO)
Limit Bypass Switch
B-25
89L
12 Volts Nominal
I/O 2 J8-17 (DI)
Rated Capacity Indicator/Limiter
B-24
89P
12 Volts Nominal
I/O 2 J8-16 (DI)
Main Charge Filter Pressure Switch
E-14
89E4
12 Volts Nominal
I/O 4 J12-10 (DI)
Main System Ground Bus
C-02
0
0 Volts
Main System Ground Bus
C-04
0
0 Volts
Main System Ground Bus
C-13
0
0 Volts
Main System Ground Bus
C-22
0
0 Volts
Main System Ground Bus
C-31
0
0 Volts
Mast Angle Sensor
A-35
88MA
5 VDC Mast at Vertical
CPU J3-58 (AI)
Mast Cylinder Extend Solenoid
C-34
55D
12 Volts Nominal
I/O 2 J8-35-36 (DO)
Mast Cylinder Retract Solenoid
C-35
55C
12 Volts Nominal
I/O 2 J8-37-38 (DO)
Mast Lower Switch
B-11
89K5
12 Volts Nominal
I/O 1 J6-17 (DI)
Mast Raise Switch
B-06
89J5
12 Volts Nominal
I/O 1 J6-12 (DI)
Motion Alarm
C-27
25X
12 Volts Nominal
I/O 2 J8-25-26 (DO)
Rear Drum Brake Pedal
A-16
81EP
0 Volts Neutral; 1.4 to 5 Volts Lower;
5 to 8.6 Volts Raise
I/O 2 J7-58 (AI)
Rear Drum Flange Encoder CH A
D-03
81MA
7.5 Volts or 0 Volts Not Moving
3.5 Volts Moving
I/O 1 J6-03 (DI)
Rear Drum Flange Encoder CH B
D-04
81MB
7.5 Volts or 0 Volts Not Moving
3.5 Volts Moving
I/O 1 J6-04 (DI)
Rear Drum Free Fall Brake Pressure
A-14
81QF
1.2 Volts at 300 psi; 1 Volt at 0 psi
I/O 2 J7-54 (AI)
Rear Drum Handle
A-04
81P
0 Volts Neutral; 1.4 to 5 Volts Lower;
5 to 8.6 Volts Raise
I/O 1 J5-52 (AI)
Rear Drum Hydraulic Clutch Solenoid
C-17
81F
12 Volts Nominal
I/O 1 J6-33-34 (DO)
Rear Drum Hydraulic Pressure
A-23
81QS
1.2 Volts at 300 psi; 1 Volt at 0 psi
CPU J3-55 (AI)
Rear Drum Maximum Bail Limit Switch
B-07
89U
12 Volts Nominal
I/O 1 J6-13 (DI)
Rear Drum Minimum Bail Limit Switch
B-08
89S
12 Volts Nominal
I/O 1 J6-14 (DI)
Rear Drum Motor Control
D-25
81MC
0 Volts to 1/3 Handle Motion
0.96 to 2.19 Volts 1/3 to Full Handle Motion
I/O 2 J8-06 (AO)
Rear Drum Park Brake Solenoid
C-19
81E
12 Volts Nominal
I/O 1 J6-37-38 (DO)
Description
Pin
Wire
Test Voltage
(DC unless otherwise specified)
Board
(Signal Type)
Содержание 999
Страница 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc 999 ...
Страница 2: ...R e f e r e n c e O n l y ...
Страница 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Страница 173: ...R e f e r e n c e O n l y Manitowoc Published 05 16 17 Control 233 03 4 19 999 SERVICE MAINTENANCE MANUAL BOOM 4 ...
Страница 174: ...R e f e r e n c e O n l y BOOM 999 SERVICE MAINTENANCE MANUAL 4 20 Published 05 16 17 Control 233 03 ...
Страница 297: ...R e f e r e n c e O n l y ...
Страница 298: ...R e f e r e n c e O n l y ...