Transmitters
122
Checking the exhaust gas temperature transmitter by measuring the voltage
0
5
10
15
20
25
30
35
0
50
100
150
200
250
300
350
400
450
500
550
600
mV
_
C
If the exhaust gas temperature transmitter is to be checked, the exhaust gas temperature must be measu-
red with a second, independent instrument. Disconnect the gauge from the transmitter. Measure the vol-
tage and compare it with the calibrated curve (
_
F = 1.8
_
C + 32).
Temperature
_
C
0
100
200
300
400
500
600
Voltage mV
0
5.37
10.95
16.56
22.16
17.85
33.67