Enter Zones 

(1-8)

Z

0

#

0

A

0

1

0

Set  the Arm Levels  A,B,C and D 

The user must key in the user code followed by ‘0' then the level A, 
B, C or D. the user must select active zones ( 

zones 1 to 8

).

Once the user enters the active Zones associated with that level 
the user then enters the hash key saving the Zones to that level. 

Save Changes

#

0

B

/

/

0

C

0

D

/

If the user enters an invalid Zone, it will be ignored.

The active zones on the level will be displayed, inactive zones will 
be displayed as a blank.

1, ,3, , ,6, ,8

   Edit Level - A

NOTE:  THIS  OPERATION  WILL  ERASE
ALL PRESENT DETECTORS ALLOCATED TO
THE ZONE CHOSEN.

!

0

#

2

1

0

1

0

Clearing Devices in a Zone

The user is prompted to enter the Zone to clear devices. Only the 
Zone entered will be cleared. Note. only one zone at a time may be 
erased 

If the user wishes to exit, the user simply pushes the hash key instead.

The user is then prompted that the zone has been cleared and the 
operation is complete.

Z

Enter Zones 

(1-8)

EXIT

#

0

#

2

2

0

1

0

Clearing Remote Controls

The user is prompted to clear the remote’s. To continue the user 
pushes the star key.

If the user wishes to exit, the user simply pushes the hash 

“#”

 key instead.

The user is then prompted that the Remote Controls have been cleared.

EXIT

#

NOTE:  THIS  OPERATION  WILL  ERASE
ALL PRESENTLY STORED REMOTE 
CONTROLS ALLOCATED TO THE UNIT.

!

*

ENTER *  TO 
CONTINUE

0

#

2

9

0

1

0

Defaulting The Entire System

The user is asked to Reset to factory settings. To continue the user pushes 
the star key.

If the user wishes to exit, the user simply pushes the hash key instead.

The user is then prompted that the System has been Reset to default settings. 

*

ENTER * TO 
CONTINUE

EXIT

#

NOTE:  THIS  OPERATION  WILL  ERASE
ALL PRESENT SETTINGS TO DEFAULT. ALL 
ALLOCATED DEVICES AND REMOTE’S WILL 
BE CLEARED AS WELL.

!

PROGRAM  THE PRESET  ARM  LEVELS A,B,C and D

CLEANING UP !! 

M000078

P7

Содержание HomeGuard 32

Страница 1: ...HOMEGUARD 32 MAMI MANUFACTURING AND MINOR INVENTIONS M000078 Wireless alarm system...

Страница 2: ......

Страница 3: ...AND D P7 CLEANING UP P7 CLEARING DEVICES IN A ZONE P7 CLEARING REMOTE CONTROLS P7 DEFAULTING THE ENTIRE SYSTEM P7 WIRELESS DETECTORS AND REMOTE CONTROL OPERATION P8 HOW TO TRIGGER DIFFERENT DEVICES FO...

Страница 4: ...no other connections are required making installation an easy task Adding wireless detectors and remote controls to the system is simple with the self learning feature OTHER FEATURES Battery operated...

Страница 5: ...iver 16bits smartcode 16 bits smartcode receivers compatible with all MAMI alarm panels Tracer Minitracer M6 To adjust these parameters refer to Programing Options Options Transmitter interface Detect...

Страница 6: ...ompatible with either the Advisor remote wireless alarm indicator or with MAMI Tracer Alarm panels 1 Tracer mode Save Changes 0 Advisor mode Set the Buzzer option 0 0 2 0 1 0 1 Buzzer will be displaye...

Страница 7: ...or automatic ARMING DISARMING Add Schedules 1or 2 will be displayed select the schedule you wish to change Schedule ARM will be displayed The user must enter the time in a 24 hour format that he wants...

Страница 8: ...device If the code already exists in the system the unit will ask the user if it must add the device The user can press star to continue or hash to exit The user is then asked to name the detector Us...

Страница 9: ...ply pushes the hash key instead The user is then prompted that the zone has been cleared and the operation is complete Z Enter Zones 1 8 EXIT 0 2 2 0 1 0 Clearing Remote Controls The user is prompted...

Страница 10: ...ZONE allocation To trigger the PIR for programming the User needs to open the casing of the PIR and consequently send a Tamper signal NOTE A tamper signal is enabled only if bit 8 of the DIPSWITCH in...

Страница 11: ...the scheduled time it will disarm automatically unless activated Keypad Disarm To disarm the unit via the keypad the user enters the user code followed by hash and hash as shown Disarmed To Disarm vi...

Страница 12: ...e keypad was triggered When the unit goes into alarm the unit will beep continuously for 1 minute and every 30 seconds thereafter The external trigger will pulled low for 30seconds on every new alarm...

Страница 13: ...or approx 2 seconds until the Beep The Level in warn mode and the Armed Zones will be shown Zones Not in the arm level will be displayed as an X 1 X 3 X X 6 X 8 Warning LEVEL A A Programming Options T...

Страница 14: ...Layout M000078 P12...

Страница 15: ...2V DC jack 220ac to 12dc 5A charger M000078 P13 M000011 outdoor detectors indoor passive infrared detector arm disarm panic remote control Silentron cRED SLIM Monitor any contact such as door smoke de...

Страница 16: ...THE SYSTEM 1000 2 9 RESET ENTIRE UNIT TO DEFAULT 1000 3 3 ACCESS THE LOG REGISTER PANIC SEND PANIC SIGNAL NOTES A A Means Press and hold the A key until it beeps A A Means Press and hold the and the...

Отзывы: