background image

GIVE  A  NAME  TO  EACH  ZONE 

0

#

0

4

0

1

0

“Zone Naming” will be displayed. then the user is prompted to 
enter a zone number  

from 1 to 8.

 If the user enters an invalid Zone, it will be ignored.

The “

#

” key is used to save that name. When the alarm goes off, the 

name and  the number of that zone will be displayed. 

Save Changes

The user must now enter a name  for that zone . A maximum of 16 
characters are allowed .
Characters are entered as in a telephone keypad. 
 

The Key ‘B’ can be used as a  backspace or delete.

B

Back space

The user is now prompted to enter a zone number  or  the  “

#

” key   

to exit. .

Continue with zone ‘Z’ 
keyed in

Naming /renaming of Zones

#

2

ABC

Exit

#

1 - 8

0

#

1 A

0

1

0

Self-learning Detectors

“ADD Device” will be display followed by TRIGGER Device, the 
user must activate the device  using either a PANIC or TAMPER 
If the panel received the code the user will be asked to enter a 
ZONE number (1 to 8). The deviceis allocated  to this Zone

The user is then prompted to choose between Replacing or  Adding 
the device
 If the code already exists in the system the unit will ask the user if 
it must add the device. The user can press star 

”*”

 to continue or 

hash 

”#”

 to exit.

The user is then asked to name the detector . Using the characters 
on the keyboard a name of 16 (max) characters may be entered 
followed by the “#” key.

Z

Enter Zones 

(1-8)

The user is then prompted to choose between Adding another 
device (

*

) key or save and Exit (

#

) key.

   TRIGGER Device

*

Continue, Add another 
Device

0

#

1

B

0

1

0

Self-learning Remote Controls

“ADD Rem Contr” will be displayed followed by TRIGGER Rem 
Contr . The user must activate the device  using the PANIC button 
(see page 8)

If the panel received the code the user will be notified that the 
remote is added.

The user is then prompted to to choose between adding another 
remote  (

*

)key    or  save and exiting (

#

)key

   Remote Added

EXIT

#

Continue

*

NOTE:  WHEN TRIGGERING DEVICES FOR 
LEARNING ONLY THE PANIC OR TAMPER 
SIGNALS WILL BE RECOGNIZED REF. PG 3

!

NOTE:  WHEN TRIGGERING DEVICES FOR 
LEARNING ONLY THE PANIC SIGNAL WILL BE 
RECOGNIZED REF. PG 3

!

LEARN A NEW DETECTOR/SENSOR  AND GIVE IT A NAME 

   ADD Device

Name device

Save and EXIT

#

or

   Add Rem Contr

   Trigger Remote

LEARN A  REMOTE CONTROL  

2

ABC

M000078

P6

Содержание HomeGuard 32

Страница 1: ...HOMEGUARD 32 MAMI MANUFACTURING AND MINOR INVENTIONS M000078 Wireless alarm system...

Страница 2: ......

Страница 3: ...AND D P7 CLEANING UP P7 CLEARING DEVICES IN A ZONE P7 CLEARING REMOTE CONTROLS P7 DEFAULTING THE ENTIRE SYSTEM P7 WIRELESS DETECTORS AND REMOTE CONTROL OPERATION P8 HOW TO TRIGGER DIFFERENT DEVICES FO...

Страница 4: ...no other connections are required making installation an easy task Adding wireless detectors and remote controls to the system is simple with the self learning feature OTHER FEATURES Battery operated...

Страница 5: ...iver 16bits smartcode 16 bits smartcode receivers compatible with all MAMI alarm panels Tracer Minitracer M6 To adjust these parameters refer to Programing Options Options Transmitter interface Detect...

Страница 6: ...ompatible with either the Advisor remote wireless alarm indicator or with MAMI Tracer Alarm panels 1 Tracer mode Save Changes 0 Advisor mode Set the Buzzer option 0 0 2 0 1 0 1 Buzzer will be displaye...

Страница 7: ...or automatic ARMING DISARMING Add Schedules 1or 2 will be displayed select the schedule you wish to change Schedule ARM will be displayed The user must enter the time in a 24 hour format that he wants...

Страница 8: ...device If the code already exists in the system the unit will ask the user if it must add the device The user can press star to continue or hash to exit The user is then asked to name the detector Us...

Страница 9: ...ply pushes the hash key instead The user is then prompted that the zone has been cleared and the operation is complete Z Enter Zones 1 8 EXIT 0 2 2 0 1 0 Clearing Remote Controls The user is prompted...

Страница 10: ...ZONE allocation To trigger the PIR for programming the User needs to open the casing of the PIR and consequently send a Tamper signal NOTE A tamper signal is enabled only if bit 8 of the DIPSWITCH in...

Страница 11: ...the scheduled time it will disarm automatically unless activated Keypad Disarm To disarm the unit via the keypad the user enters the user code followed by hash and hash as shown Disarmed To Disarm vi...

Страница 12: ...e keypad was triggered When the unit goes into alarm the unit will beep continuously for 1 minute and every 30 seconds thereafter The external trigger will pulled low for 30seconds on every new alarm...

Страница 13: ...or approx 2 seconds until the Beep The Level in warn mode and the Armed Zones will be shown Zones Not in the arm level will be displayed as an X 1 X 3 X X 6 X 8 Warning LEVEL A A Programming Options T...

Страница 14: ...Layout M000078 P12...

Страница 15: ...2V DC jack 220ac to 12dc 5A charger M000078 P13 M000011 outdoor detectors indoor passive infrared detector arm disarm panic remote control Silentron cRED SLIM Monitor any contact such as door smoke de...

Страница 16: ...THE SYSTEM 1000 2 9 RESET ENTIRE UNIT TO DEFAULT 1000 3 3 ACCESS THE LOG REGISTER PANIC SEND PANIC SIGNAL NOTES A A Means Press and hold the A key until it beeps A A Means Press and hold the and the...

Отзывы: