ATTENTION 
If  the  controller  is  set  in  heating  mode,  the  hysteresis  operation  has  the  opposite  character,  
i.e. the heating system is switched off after the temperature has dropped below the set value, 
taking into account the value of the programmed hysteresis. 

 
 
4.2. Control of the stirrer motoreducer. 

The operation status of the stirrer is indicated by a red diode (see section 3.). 
The controller has two modes of  stirrer operation (automatic or manual), which are described in 
detail below.

 

 
4.2.1. Automatic operation of the stirrer. 

In this mode, depending on the settings of parameters F0E1 and E2, the stirrer may be connected 
to the operation of the chiller or completely independent of it (see section 3.4). 
The stirrer operation setting in the automatic mode is signaled by a continuous lighting of the stirrer 
operation red diode.

 

 
4.2.2. Manually triggered operation of the stirrer. 

The manual stirrer operation can be initiated  by pressing the button marked with the symbol 

  

(seesection 3.); at this point, the automatic stirrer operation is stopped and the manual operation is 
switched over. Manual mode is signaled by a blinking of th stirrer operation red diode. 
Manual  operation  of  the  stirrer  is  possible  when  the  controller  is  turned  off,  as  well  as  when  
the  washing  process  is  switched  on  –  depending  on  the  washing  program  set  up  and  the 
configuration made. 
The stirrer operation in this mode can be interrupted at any time by pressing the button   again. 
The manual stirrer operation can take place in two variants, depending on the CP parameter settings: 

 

setting the value 0 means continuous operation of the stirrer, 

 

setting  the  value  >0  means  that  the  stirrer  operates  for  the  set  number  of  minutes; 
after the set time elapses, the manual operation of the agitator is automatically switched 
off. 

 

 
 
 
 
 
 
 
 
 
 

Содержание MCH-07 v.3

Страница 1: ...tally to activate the washing process during the cooling process The washing segment is activated only when the cooling is switched off The MCH 07 controller has a waterproof casing protection class I...

Страница 2: ...ge 2 of 36 MCH 07 casing dimensions 177 x 126 x 56 mm MCH 07 f casing dimensions 206 x 140 x 56 mm power supply 230V AC 50 60 HZ protection class IP65 safety class CE basic version of MCH 07 controlle...

Страница 3: ...Page 3 of 36 MCH 07 f variant with flange...

Страница 4: ...PCB board with the bottom board After opening the casing disconnect this cable The cable is disconnected by removing the connector plug located in the bottom plate basic version of MCH 07 controller...

Страница 5: ...Page 5 of 36 dimensioning for assembly MCH 07 f variant with flange connection diagram...

Страница 6: ...al data of the cooling segment temperature measuring range from 40 0 OC to 120 0 OC control temperature range from 40 0 OC to 120 0 OC decreased by a set hysteresis measuring resolution of the tempera...

Страница 7: ...1 2 Control function of the refrigeration system chiller depending on the measured temperature parameter C9 is set to 0 3 Light signaling function for switching on the cooling heating process blue di...

Страница 8: ...ing of the voltage parameter dE 11 Real time clock 3 3 Programming for the cooling segment In order to ensure the correct cycle of the controller s operation it is necessary to program its operating p...

Страница 9: ...nction symbol range of the settings factory setting entry in the setting mode UC0 access code 1 2 controller operation mode C9 0 cooling mode 1 heating mode 0 limitation of the lower value for the con...

Страница 10: ...dstill of the chiller unit the stirrer works according to times set in E1 and E2 2 unavailable3 3 unavailable 3 4 continuous operation independent of the chiller operation and times set in E1 and E2 1...

Страница 11: ...y settings and the function value is reset to 0 0 exit from the setting mode EE 1 Adjustments must be made so that the condition b1 b2 is always met The values of parameters b1 and b2 are not control...

Страница 12: ...e cooling temperature in the range of 40 OC up to 120 OC In order to limit the range of control so as to prevent the user of the refrigeration device from setting the temperature outside this range th...

Страница 13: ...ing of the stirrer operation red diode 4 2 2 Manually triggered operation of the stirrer The manual stirrer operation can be initiated by pressing the button marked with the symbol seesection 3 at thi...

Страница 14: ...ure values are stored in the controller s memory The programmable delay time of this function allows not to take into account the maximum temperature when the controller is started and thus to pre coo...

Страница 15: ...ggered cyclically every 1 min for 5 sec and alternately PPP letters and temperature value are displayed ATTENTION The parameter AA is the same to the delay time specified in the function of recording...

Страница 16: ...ducer after voltage decay Controller has the ability to protect the chiller and motoreducer in the event of momentary decays and the appearance of the supply voltage this is done by setting the dE par...

Страница 17: ...n MCH 07 MCH 07T1 version with the possibility of water heating control and thermostatic control equipped with one sensor common with the cooling segment MCH 07T2 version with the possibility of water...

Страница 18: ...hydrostatic in MCH 07T version it is possible to set the controller to indicate the current temperature measured by the temperature sensor LED diodes marked with numbers 1 8 indicating which relays ar...

Страница 19: ...230 VAC supply voltage switching voltage input for relay 5 any of the range from 6V to 380V which can be different from the voltage connected to relays 1 4 and 6 8 input for hydrostatic connection in...

Страница 20: ...ings made the program execution remains off or starts in the same place where it was stopped You can limit the return time in the settings of this function for interrupted operation after voltage deca...

Страница 21: ...isplay shows the time to complete the entire program The time indicated by the display does not take into account the time of pouring water when using a hydrostatic as well as the time needed to heat...

Страница 22: ...s possible in the range of 10 OC every 0 5 OC where 0 5 OC is indicated by lighting up a dot by digit of temperature Corrections of the readings should be made only after the actual confirmation of fa...

Страница 23: ...ight to left on the display to edit the duration of the step switching between diodes to determine the relay status signaled by a diode entering the settings related to temperature functions MCH 07T v...

Страница 24: ...9 59 min 01 00 min setting the maximum power supply decay time after which the program will be resumed UAP 0 no time limit the program will be always resumed after the power supply is restored 1 time...

Страница 25: ...only if PUL5 1 PHo setting the time for which relay 7 will be inactive from 1 sec to 59 sec 1 s 6 7 Selection and setting of the example function The following is a graphical representation of the ch...

Страница 26: ...nce in the case of a step with a hydrostatic active this is a protection in the event of a mechanical suspension of the hydrostatic Additionally for the MCH 07T version optionally you can assign to an...

Страница 27: ...modified program beforehand For convenience the table should look similar to the tables of the factory programs It should be remembered that after 30 sec without any related activities with programmi...

Страница 28: ...ection by pressing the S button and change the value of this parameter from 0 to 1 using the button Then confirm the changes by pressing the S button again After doing this disconnect the power supply...

Страница 29: ...lock it indicates that the battery is running low It should be replaced alone or sent to a service center for payable replacement 7 2 Choosing the washing program At any time the user can read which w...

Страница 30: ...instead of time This function can only be assigned to one or more steps and in the remaining steps the time to finish the washing process can still be displayed Starting the washing process is also si...

Страница 31: ...lay output no 3 made by the installer either the vacuum pump PP or the stirrer PPR can be switched on manually Switching off occurs by pressing the button again or automatically after the time set by...

Страница 32: ...er relay ZW cold water relay PP vacuum pump relay PML milk pump relay PM washing pump relay PPR stirrer relay ZZ dump valve relay H hydrostatic ZD1 detergent dispensing valve 1 relay w free ZD2 deterg...

Страница 33: ...f pouring water with the hydrostatic switched on it is not necessary to know the time needed to pour water PRO2 WASHING A MILKING DEVICE diode no 1 2 3 4 5 6 7 8 9 comments relay no 1 2 3 4 5 6 7 8 mo...

Страница 34: ...12 15 00 1 1 max time 13 05 00 1 1 14 00 30 1 1 1 total time 27 20 total time does not take into account the time of pouring water with the hydrostatic switched on it is not necessary to know the time...

Страница 35: ...uring water with the hydrostatic switched on it is not necessary to know the time needed to pour water PRO2 WASHING A MILKING DEVICE diode no 1 2 3 4 5 6 7 8 H comments relay no 1 2 3 4 5 6 7 8 mode s...

Страница 36: ...4 05 00 1 1 15 00 30 1 1 1 total time 27 20 total time does not take into account the time of pouring water with the hydrostatic switched on it is not necessary to know the time needed to pour water P...

Отзывы: