25
Using BRAINS to Sequence Splices:
Similar to the patch
above, this patch uses
the BRAINS to sequence
playback.
Note: PRESSURE
POINTS Row Y Tuned
Voltage has a Range of
0-5V, which is what the
ORGANIZE CV INput
expects.
Using BRAINS to Sequence GENES:
This patch is very similar
to the RENE patch from
page 24, which uses
GENES to separate and
sequence each sound in
the loop.
Note: PRESSURE POINTS
Row X Tuned Voltage
has a range of 0-8V,
which is what the SLIDE
CV INput expects.
Advanced Patch Techniques:
(CONT’D)
16 Touch Plates:
To Manually Splice and Trigger and Sample, first record a loop as before. If there is a little too much space before or after the
sample, use the Splice button to trim the Start and End points to create a Splice that loops nicely. Next, turn Gene Size and
SLIDE fully-clockwise. Slowly rotate Slide counter-clockwise through the entire Range, along the way, [Pressing] Splice at the
first loud transient in a series of tiny Genes. This process is demonstrated here:
(https://www.youtube.com/watch?v=zSPeaVAn0ds).
Now, with Organize counter-clockwise and its associated Attenuator full clockwise, patch PRESSURE POINTS Tuned Voltages
Output Y to the Organize CV Input, and the CH.4 Common Gate Output to the PHONOGENE’s Play Input. Each Touch Plate
may now be set to select and Trigger a new Splice, using the associated Row Y Tuned Voltage Panel Controls. Chain up to four
PRESSURE POINTS to select up to (16) different Splices within the original sample.