Emergency operation of the generator engine
Plant service permitting, the set with a defective turbocharger should be shut down and separated
from the mains.
If an engine shut-down is not possible, disconnect all consumption as far as is possible, so that the
motor can operate with a
P
me
≈
3 bar at nominal speed abt. 15 %.
•
Stop the engine
•
Remove the air filter silencer
•
Replace the KKK turbocharger:
No blockage of the charger is possible, therefore loosen the connection of the turbine housing
bearing housing and complete with the unit air filter, compressor housing, and bearing
housing, dismantle from the engine. Remove the protective shield and replace it with the
protective shield contained in the tool kit (KKK), this shield having no central bore hole.
Block all oil feeds and return lines. All possible openings on the transitional air housing of the
charger are to be opened.
•
KBB turbocharger shut-down; for this see KBB service information in
.
•
Start the engine and reduce the output. If the installation is for heavy fuel, we recommend the
change to distillate fuel in emergency operation.
Monitoring the engine while the turbocharger is defective
Change the fuel rack position gradually until the
exhaust gas temperature after the turbine is a maximum 500 °C
Carefully monitor the exhaust gas temperatures during emergency operation, especially if exhaust
gas alarms have been cut out.
Charge air temperature while the turbocharger is defective
The turbocharger air temperature is reduced - not however under 30 °C.
Finishing with emergency operation
After an emergency operation with heavy fuel, at least one cylinder head must be removed for
reasons of safety and to ascertain whether a general overhaul of the valves is necessary.
^
=
Содержание M20
Страница 5: ...Technical engine data A1 M20 M601C en 31 10 2001 AA000103 1 1 Technical engine data...
Страница 6: ...Governor data A1 04 en 18 02 2000 AA000097 1 1 Governor data not installed on CD Rom...
Страница 10: ...Acceptance Test Records A1 10 en 16 11 1999 AA000095 1 1 Acceptance test records not installed on CD Rom...
Страница 11: ...Operating instructions A3 M20 M601C en 31 10 2001 AA000108 1 1 Operating instructions...
Страница 30: ...Initial operation Engine A3 05 00 en 14 02 2001 BA000022 1 1 Initial operation...
Страница 44: ...Operational supervision Engine A3 06 00 en 15 02 2001 BA000058 1 1 Operational supervision...
Страница 64: ...Removal from operation Engine A3 07 00 en 16 02 2001 BA000094 1 1 Removal from operation...
Страница 71: ...Danger of frost Engine A3 08 00 en 16 02 2001 BA000106 1 1 Danger of frost...
Страница 83: ...Running in Engine A3 10 00 en 16 02 2001 BA000242 1 1 Running in...
Страница 85: ...Fault tracing Engine A3 11 00 en 19 02 2001 BA000130 1 1 Fault tracing...
Страница 91: ...Emergency operation Engine A3 12 00 en 19 02 2001 BA000142 1 1 Emergency operation...
Страница 102: ...Operating media A4 en 31 10 2001 AA020105 1 1 Operating media...
Страница 106: ...Regulations and care Engine A4 05 00 en 21 02 2001 BA000158 1 1 Regulations and care...
Страница 137: ...Maintenance A5 en 31 10 2001 AA000026 1 1 Maintenance...
Страница 166: ...Periodical schedule Heavy fuel A5 04 02 M20 en 31 10 2001 AA021679 8 8...
Страница 242: ...Bearing Shells Inspection Evaluate A5 05 02 03 07 01 M20 en 13 06 1997 IB001449 3 4 02 1 2 3...
Страница 243: ...Bearing Shells Inspection Evaluate A5 05 02 03 07 01 M20 en 13 06 1997 IB001449 4 4 02 4 5 6...
Страница 435: ...Table of contents A6 01 en 31 10 2001 AA020050 1 1 Tools A6 Table of contents A6 01...