![MAK M20 Скачать руководство пользователя страница 132](http://html1.mh-extra.com/html/mak/m20/m20_operating-instructions-manual_3784461132.webp)
en / 20.01.2000
BA000202
3/3
2.
Checking and care of the treated water
2.1
Anti-corrosion oil
A
daily
check of the coolant level in the sight glass on the expansion tank is just as important
as checking the
anti-corrosion oil contents
every
600 operating hours
. During prolonged
operating breaks, a
monthly
check should be made.
Take the emulsion sample out of the supply line from expansion tank to pump and let it stand
for
1 h
. Pour off oil which rises to the surface.
Carry out emulsion test e.g. with hand refractometer (specialist shop laboratory equipment) .
0 %
–
Cooling water change and cleaning necessary, see
< 0,5 % –
Emulsion freshening required
0,5 - 1 %–
Emulsion in order
> 1 %
–
Concentration too high, possibly incorrect measurement
In case the measured values are higher than
1.5 %
, test again with fresh sample water. If the
result is confirmed, a correction of the emulsion is necessary.
Emulsion freshening in case of concentration too low
Mix required amount of oil according to diagram II (
) with conditioning water to a
highly concentrated emulsion.
Always add oil to water
Fill in the mixed emulsion via the compensator reservoir, also possible with engine running.
Emulsion correction in case of concentration too high
Drain cooling water emulsion according to diagram II (
) and refill the circuit with
conditioning water.
2.2
Chemical corrosion inhibitors.
The maintaining of the determined concentration is of decisive importance for a proper
corrosion protection.
A concentration check of the chemical corrosion inhibitors under consideration of the limit
values (see 1.2) is to be carried out with the relevant testing equipment every 150 h in
accordance with the instructions of the supplying companies.
After a freshening up of the concentration mix well with engine running!
Содержание M20
Страница 5: ...Technical engine data A1 M20 M601C en 31 10 2001 AA000103 1 1 Technical engine data...
Страница 6: ...Governor data A1 04 en 18 02 2000 AA000097 1 1 Governor data not installed on CD Rom...
Страница 10: ...Acceptance Test Records A1 10 en 16 11 1999 AA000095 1 1 Acceptance test records not installed on CD Rom...
Страница 11: ...Operating instructions A3 M20 M601C en 31 10 2001 AA000108 1 1 Operating instructions...
Страница 30: ...Initial operation Engine A3 05 00 en 14 02 2001 BA000022 1 1 Initial operation...
Страница 44: ...Operational supervision Engine A3 06 00 en 15 02 2001 BA000058 1 1 Operational supervision...
Страница 64: ...Removal from operation Engine A3 07 00 en 16 02 2001 BA000094 1 1 Removal from operation...
Страница 71: ...Danger of frost Engine A3 08 00 en 16 02 2001 BA000106 1 1 Danger of frost...
Страница 83: ...Running in Engine A3 10 00 en 16 02 2001 BA000242 1 1 Running in...
Страница 85: ...Fault tracing Engine A3 11 00 en 19 02 2001 BA000130 1 1 Fault tracing...
Страница 91: ...Emergency operation Engine A3 12 00 en 19 02 2001 BA000142 1 1 Emergency operation...
Страница 102: ...Operating media A4 en 31 10 2001 AA020105 1 1 Operating media...
Страница 106: ...Regulations and care Engine A4 05 00 en 21 02 2001 BA000158 1 1 Regulations and care...
Страница 137: ...Maintenance A5 en 31 10 2001 AA000026 1 1 Maintenance...
Страница 166: ...Periodical schedule Heavy fuel A5 04 02 M20 en 31 10 2001 AA021679 8 8...
Страница 242: ...Bearing Shells Inspection Evaluate A5 05 02 03 07 01 M20 en 13 06 1997 IB001449 3 4 02 1 2 3...
Страница 243: ...Bearing Shells Inspection Evaluate A5 05 02 03 07 01 M20 en 13 06 1997 IB001449 4 4 02 4 5 6...
Страница 435: ...Table of contents A6 01 en 31 10 2001 AA020050 1 1 Tools A6 Table of contents A6 01...