background image

majestic 

installation guide

deauville corner enclosure

for units with 

24

mm wall 

and floor surface profiles,  

without an underframe

Содержание Deauville Corner Enclosure

Страница 1: ...majestic installation guide deauville corner enclosure for units with 24mm wall and floor surface profiles without an underframe ...

Страница 2: ...2SL England Telephone 44 0 8448 001 500 Facsimile 44 0 1279 635 074 info majesticshowers com www majesticshowers com These Instructions are for a left and right handed unit The diagrams show a left handed unit You will have to determine which hand of unit you have before work commences ...

Страница 3: ...before installation if any of the parts have been supplied incorrectly or are damaged contact Majestic immediately Any faults with the product found after installation cannot be rectified and Majestic will not be held responsible for re installation of faulty or marked goods Unwrap all parts carefully to avoid damaging the chrome fittings This unit must be fitted on a level surface unless the glas...

Страница 4: ...y the outer edge of the profiles should sit 10mm back from the front edge of the tray 1 The horizontal profiles are supplied at maximum adjustment length and have been mitred as a guide but it is likely you will have to cut them down Before setting out the horizontal profiles you will have to determine how much you will need to cut off in line profile A and the return profile 2 If you cut 9mm off ...

Страница 5: ...lift the glass return panel into the profile Make sure the return panel is plumb vertical pack it up with 3 rubber strips if necessary taking note of their positions Do not use more than three strips of rubber under the panel Size of profile A after cutting In line profile B Door panel C 9mm Glass Return Panel 10mm Spacer D D 5 Measure the width of the inline profiles A and B and the glass door pa...

Страница 6: ... holes where marked on the wall insert Rawl plugs 12 Run a bead of silicone along the wall side of the vertical wall profile and screw it tightly into place Loosely screw the glass to wall brackets to the wall Glass Return Panel 10mm Spacer 9 Using a metal scriber mark the vertical profile level with the top of the glass The glass return panel can be moved backwards or forwards in the return profi...

Страница 7: ...el as shown Use the 10mm spacer to help Glass Return Panel 10mm Spacer 13 Run a bead of silicone along the base of the horizontal return profile and reposition it on the tray or floor where marked use the 10mm spacer to ensure it is aligned with the vertical wall profile and push the mitred ends together tape into position Remove the 10mm spacer and apply a generous amount of silicone into the cor...

Страница 8: ...ith inline profile B Also check at this point that the gap between the profiles A B is equal to the width of the glass door panel 9mm 19 Insert the 10mm spacer into horizontal inline profile A and use it to align the second vertical wall profile Push the mitred ends together and use a spirit level to ensure the wall profile is plumb vertical Mark the screw holes remove the vertical wall profile Dr...

Страница 9: ... clear plastic gaskets inserted and wall screw plates facing inwards align the brackets centrally to the holes in the glass return panel hold them in place and mark the screw holes A B 23 Run a bead of silicone along the wall side of the vertical wall profile and screw it tightly into place Loosely screw the glass to wall brackets to the wall A B 24 Run a bead of silicone along the base of horizon...

Страница 10: ...lass to wall brackets through the holes in glass in line panel A Ensure glass inline panel A is plumb vertical and level with the return panel then fully tighten the glass to wall bracket faceplates 28 Disassemble the glass to glass bracket being careful not to damage the polished surfaces Fit the inner part of the bracket to the glass return panel so the clear plastic gasket is aligned with the e...

Страница 11: ...note of their positions Check the panel sits plumb vertical 2 Door Panel Fixed Panel 90 90 Hinge packer Hinge packer 30 Using the suction glass lifters remove glass inline panel B Un tape and remove the horizontal inline profile 31 Run a bead of silicone along the underside of the horizontal inline profile and reposition it on the floor where marked tape in place Use the 10mm spacer to ensure it i...

Страница 12: ... Panel 90 90 Hinge packer Hinge packer 35 Insert a black rubber hinge packer into the in line panel hinge slots as shown Disassemble the hinges being careful not to damage the polished surfaces Place the hinges and faceplates either side of the hinge slots in the glass in line panel with gaskets inserted and Allen bolts facing inwards loosely screw the hinges and faceplates together Use a set squa...

Страница 13: ...lush and the end of the glass door should not protrude beyond the hinges Tighten the Allen bolts 38 The other 1936 door to glass seal 2 should be cut into three pieces to fit vertically above between and below the hinges on the end of the door Open the door outwards and slide the sections into place on the door If necessary adjust the door on its hinges so that it closes correctly onto the in line...

Страница 14: ...rt bar and the 45 support arm if supplied 43 Make sure all screws and fittings are tight especially the 4mm Allen bolts on the hinges Tighten to 12 N m Dab the cover caps with silicone and place the caps on the 90 glass to glass and glass to wall brackets Caps are not provided for the polished hex Allen bolts on the hinges 44 Tape the glass return and in line panels together as shown and run a bea...