MP1900X Series Router Installation Manual
Router Installation
copyright
2019 Maipu, all rights reserved
3-9
The hanging ear does not bear the weight. Do not bear the router only using a
hanging ear without installing the slide (tray).
Check the Installation
After the router is installed to the cabinet, check the installation based on the following
items and ensure all the items are normal.
Check and ensure that the router is installed correctly.
Check and ensure that the router hanging ear and cabinet are secure and well.
Check and ensure that enough space is reserved around the router for heat
dissipation.
3.2
Ground the Router
For the router and human security, the router must be grounded well. The
resistance between the router chassis and the ground should be less than1 ohm.
Generally, there is the grounding bar on the cabinet and we can connect the ground
cable of the router to the grounding bar.
Please use the ground cable carried by the router.
The steps of installing the ground cable are as follows:
Step 1: Remove the ground screw on the chassis of the router.
Step 2: Bind the wiring terminal of the ground cable carried by the router to the ground screw of
the chassis.
Step 3: Install the ground screw with the ground cable to the grounding hole and tighten it.