background image

CBA UP - 10.752

Manual english - www.maintronic.com

 / 

22 53

6.3 Select an operating mode

Select application profiles

The device has different operating modes (so-called Casambi profiles), with the profiles the functionality and the parameters of the 
device are determined.

Before programming, a Casambi profile must be selected (by default the profile - CBA Blind + Buttons is set).

Select a suitable profile for your application:

Application profiles listing

Fixture ID

Icon

Profile name

Control name

Function

Control type

19473

CBA Blind

Position
Angle

Position
Slat angle

Slider (0% - 100%)
Slider (0% - 100%)

18445

CBA Blind + Buttons

Position
Angle
Up
Down
Angle

Position
Slat angle
Single trip Up
Single trip Down
Slat angle

Slider (0% - 100%)
Slider (0% - 100%)
ON/OFF Toggle
ON/OFF Toggle
Push Button

24843

CBA Blind + B Group

Position
Angle
Up
Down
Angle
Master

Position
Slat angle
Single trip Up
Single trip Down
Slat angle
Group
Master Function

Slider (0% - 100%)
Slider (0% - 100%)
ON/OFF Toggle
ON/OFF Toggle
Push Button
ON/OFF Toggle

19474

CBA Buttons

Up
Down
Function A
Function B

Single trip Up
Single trip Down
Function for the button A
Function for the button B

ON/OFF Toggle
ON/OFF Toggle
Push Button
Push Button

24872

CBA B Group

Up
Down
Function A
Function B
Master

Single trip Up
Single trip Down
Function for the button A
Function for the button B
Group
Master Function

ON/OFF Toggle
ON/OFF Toggle
Push Button
Push Button
ON/OFF Toggle

19476

CBA Shutter

Position

Position

Slider (0% - 100%)

19477

CBA S Buttons

Position
Up
Down

Position
Single trip Up
Single trip Down

Slider (0% - 100%)
ON/OFF Toggle
ON/OFF Toggle

24873

CBA S B Group

Position
Up
Down
Master

Position
Single trip Up
Single trip Down
Group
Master Function

Slider (0% - 100%)
ON/OFF Toggle
ON/OFF Toggle
ON/OFF Toggle

Содержание CBA UP

Страница 1: ...ieaktor UP supported product version H1 F2 5 Dokument Version 20221014 Manufacturer s address and contact details Adress MTC maintronic GmbH Carl Zeiss Straße 10 D 97424 Schweinfurt Germany Contact details E Mail Web Phone info maintronic com www maintronic com 0049 9721 7766 0 ...

Страница 2: ...derations and planning 14 5 2 Mechanical installation 15 5 3 Electrical installation 17 6 Commissioning CBA UP 20 6 1 Operation with Casambi 20 6 2 Commissioning 20 6 3 Select an operating mode 22 6 4 Change operating mode 32 6 5 Calibration 34 7 Operation CBA UP 35 7 1 Notes for operation 35 7 2 Sensors and parameters 38 7 3 Operation with app 39 7 4 Operation with Push button input 41 7 5 Operat...

Страница 3: ...bed here Before installation commissioning and operation read this manual and pay attention to the warnings for safe handling which are marked as follows 1 3 Safety information DANGER The signal word DANGER indicates an imminent danger If not avoided death or serious injury will result WARNING The signal word WARNING indicates a possibly imminent danger If it is not avoided death or very serious i...

Страница 4: ...tch Device powers up or down by zero crossing of the sinewave Weight in gramm Icon Description Astro function control scenes through sunrise and sunset Group devices create groups for joint control Logical inverting of channels e g for a blind up down or CH1 and CH2 Timer function execute time controlled automated functions Scene control save individual fixed images as scenes or create a chaser wi...

Страница 5: ...ush mouted housing in installation boxes or in devices of protection class II Installation housing installation in ceiling wall or luminaire NOTE The symbols explained here show the technical data of the devices These symbols can be found in the technical documentation of the respective device DALI protocol interface with device type 6 DMX protocol interface DMX protocol interface with RDM RS485 i...

Страница 6: ...Manual english www maintronic com 6 53 Switch Relay normally open contact Number indicates the amount of relays and 16A the switch current of the relay Relay with high inrush current current peaks up to 165A for 20mS ...

Страница 7: ...rken Warenzeichen oder Logos liegen bei den jeweiligen Eigentümern 1 8 Service and support If you need special support beyond the information provided here contact your distributor or the address in the Manufacturer Contact section Herstellerkontakt 1 9 Disposal Waste disposal In accordance with European Directive 2002 96 EC it s not longer usable electronic devices and defective or used batteries...

Страница 8: ...laces with a good ventilation and without humidity or high temperatures Do not expose the unit to rain or snow Do not operate the unit near heat sources e g radiators If any of the following occurs do not operate the device without first checking it if objects have fallen or liquid has been spilled into the unit if the device has been exposed to rain if the device does not operate normally or with...

Страница 9: ...efective or used batteries European Directive 2006 66EG must collected separately and disposed by an environmentally sound recycling This symbol indicates that electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime Should these product are no longer be useable the user is required by law to dispose of old appliances separately fr...

Страница 10: ...nsteuerung über und über Tasteingang Push button input Casambi Modul Version Einbauort Beschreibung UP Unterputz für den Einbau in tiefe Schalterdosen oder Abzweigdosen Das Gerät ist für Folgendes bestimmt dem Betrieb gemäß den aufgeführten technischen Daten die Installation in trockenen Innenräumen die Nutzung mit den am Gerät vorhandenen Anschlussmöglichkeiten HINWEIS Zur bestimmungsgemäßen Verw...

Страница 11: ... zur Version findet sich auf dem Geräteaufkleber rechts unten 2 Stimmt die Version Ihres Gerätes nicht mit der im Handbuch unterstützen Version überein beschaffen Sie sich das zugehörige Handbuch und verfahren nach der Anleitungen dort 2 3 Not intended use Jede andere Verwendung gilt als bestimmungswidrig und kann zu Personen und Sachschäden führen insbesonders eigenmächtige bauliche Veränderungen...

Страница 12: ...ed Groups can be formed scenes and timers can be created You can find all Casambi app related help on the official Casambi support sites at https support casambi com These functions enable for example to group 5 blinds on one side of the building and operate them together In addition automated up and down movements can also be programmed as a time controlled scene For help with the configuration a...

Страница 13: ...rols and indicators DeviceButton Status LED Protocol Casambi App available for Android and IOS Alternate control Casambi enabled Push button inputs 2 x Inputs on mains voltage L Environment Type of protection IP20 Protection class Class II Temperature ambient ta 0 50 Celsius Temperature critical tc 70 Celsius Humidity 5 80 non condensing n c Applied standards CE Design Construction Flush mounted h...

Страница 14: ... is based on the energy saving Bluetooth 4 0 standard If a module is nearby all luminaires within range of this module can be controlled Bluetooth has a range of up to 20 m Plan your network in such a way that the radio coverage of the modules is guaranteed with each other and no dead spots arise If there are gaps in the network or modules are positioned at the limit of the radio coverage strange ...

Страница 15: ...ng for installation in switch boxes or junction boxes Attachment with two eyelets these can be removed for installation Installation Even if the device has tiny dimensions a deep installation box 60 mm is highly recommended Depending on which push button is used up to 30 mm of the available space must be deducted ...

Страница 16: ...3 For installation in cavity or switch boxes the eyelets needs to be removed Install the device with labeling LED and device button must point to the front Remove the eyelets and flip the device install with labeling LED and device button faces forwards ...

Страница 17: ...rive Down 6 L Switched Output phase 230V AC 7 T1 Push button input T1 8 T2 Push button input T2 NOTE The relay outputs are mutually blocked to ensure that only one path is active at a time motor protection WARNING Please note that mains voltage is always applied to the pin of the switched phase L pin 6 as long as no active movement is carried out via the Casambi control level Connection diagram ...

Страница 18: ...CBA UP 10 752 Manual english www maintronic com 18 53 Wiring 0 5 1 5mm Solid conductor 0 5 1 5mm Fine stranded conductor 0 5 0 75mm Fine stranded conductor with ferrule 8mm ...

Страница 19: ...CBA UP 10 752 Manual english www maintronic com 19 53 Operating elements Controls 1 Device button 2 Status LED ...

Страница 20: ...tions triggered by the buttons are individually configurable As soon as the device is added to your network it can be operated Groups can be formed scenes and timers can be created You can find all Casambi app related help on the official Casambi support sites at https support casambi com 6 2 Commissioning To make sure that the functionality of the device is up to date first of all you have to che...

Страница 21: ... identifies the device and can be integrated into existing networks All functions triggered by the buttons are individually configurable The following steps are necessary for this purpose Open Casambi App Choose existing network or create a new network Go to nearby devices Add found maintronic device to a network ...

Страница 22: ... Buttons Group Position Angle Up Down Angle Master Position Slat angle Single trip Up Single trip Down Slat angle Group Master Function Slider 0 100 Slider 0 100 ON OFF Toggle ON OFF Toggle Push Button ON OFF Toggle 19474 CBA Buttons Up Down Function A Function B Single trip Up Single trip Down Function for the button A Function for the button B ON OFF Toggle ON OFF Toggle Push Button Push Button ...

Страница 23: ...BA UP together in a group Profiles für Roller Blinds CBA Shutter Operation via app drive roller blind to absolute position Slider CBA Shutter Buttons same as CBA Shutter Integration of external buttons and use of scenes CBA Shutter Buttons Group same as CBA Blind Shutter Operate several CBA UP together in a group Special profiles CBA Buttons Operation via app only via Toggle Switch and button The ...

Страница 24: ...ols Parameter Application Blind with pure slider operation one slider each for position and louvre angle angle Info The fixture CBA Blind has no additional controls for control via external buttons or scenes For this the fixture CBA Blind Buttons ID 18445 or CBA Blind Buttons Group ID 24843 would have to be used ...

Страница 25: ...d with slider operation via app Toggle switch for scene programming and button operation Info In addition to the two sliders for position and angle the fixture CBA Blind Buttons has a toggle switch for each direction of travel and a push button for the slat adjustment The switches and buttons can be used to program scenes when automated drives are to be used ...

Страница 26: ...scene programming and button operation Additional group function with master switch Info In addition to the two sliders for position and angle the fixture CBA Blind Buttons Group has a toggle switch for each direction of travel a push button for the lamella adjustment and a master switch toggle switch for a group function The switches and buttons can be used to program scenes when automated drives...

Страница 27: ... Controls Parameter Application Roller blind with pure slider operation a single slider for position Info The fixture CBA Shutter has no additional controls for control via external buttons or scenes For this the fixture CBA Shutter Buttons ID 19477 or CBA Shutter Buttons Group ID 24873 would have to be used ...

Страница 28: ...ter Application Roller blinds with slider operation via app Toggle switch for scene programming and button operation Info In addition to the slider for position the fixture CBA Shutter Buttons has a toggle switch for each direction of travel The switches and buttons can be used to program scenes when automated drives are to be used ...

Страница 29: ...n via app Toggle switch for scene programming and button operation Additional group function with master switch Info In addition to the slider for position the fixture CBA Shutter Buttons Group has a toggle switch for each direction of travel and a master switch toggle switch for a group function The switches and buttons can be used to program scenes when automated drives are to be used ...

Страница 30: ...ntronic com 30 53 Casambi Profile CBA Buttons Fixture ID 19474 App Icon Bedienelemente Parameter Application Push button operation without slider function Possibility of switching driving till the end and buttons press drive release stop ...

Страница 31: ... Profile CBA Buttons Group Fixture ID 24872 App Icon Bedienelemente Parameter Application Push button operation without slider function Possibility of switching driving till the end and buttons press drive release stop Additional group function with master switch ...

Страница 32: ...files with the profiles the functionality and the parameters are determined In order to select a specific operation mode a Casambi profile must be selected via the Casambi app when teaching the device Preparation Device must be unpaired Open Casambi App and select More Open Nearby Devices Change Profile Tap on the desired device Select Change Profile ...

Страница 33: ...e information about the operating modes refer to the manual in the Commissioning section Select a desired profile from the list provided Tap on the desired profile Select Start Update Add the device to a network Wait for the update to complete successfully Select Use in my network Device is now connected to your network ...

Страница 34: ...n can be measured again Enter the measured time plus approx 1 second as a buffer in the device settings under parameter Drive Time After changing the drive time a complete drive 0 fully open 100 fully closed needs to be completed again Setting the slat position Angle time The Angle Time is the aperture angle of the blind slats this time must be measured and set in the parameters Move the blind up ...

Страница 35: ...in the device Driving to a specific position With one trip to an absolute position any horizontal position can be approached The specific position is controlled by a slider from OT 0 UT 100 which determines the status of the connected blind roller blind etc Slat adjustment The angle of the slats can be adjusted via the slider angle only available for fixtures with blinds This slat position is stor...

Страница 36: ...73 CBA Shutter Buttons Group 24872 CBA Buttons Group Set one of the above mentioned Group fixtures on the device which shall be configured as master on all other devices no profile with the addition Group should be used Couple all desired blind actuators with a Casambi network Perform a calibration reference run measure time see instructions 6 5 Set Drive Time and Angle Time manually in the parame...

Страница 37: ...be activated switched The controls Up Down and Angle of the master now control the entire group Individual operation of the master via app In order to drive the connected blind of the master device individually via app the toggle switch Master must first be deactivated After that the individual blind can be operated as usual ...

Страница 38: ...Parameter Parameter Designation Description Values Notes Default Drive Time Drive time for a passage of the blind up or down 0 255s Seconds 60s Default Angle Time Drive time for slat adjustment 0 65535ms Milliseconds 2000ms Default Function A Function for the push button input T1 Not in Use Blind Up Blind Down Toggle direction Blind Up with time Blind Down with time Toggle direction with time Not ...

Страница 39: ...e case of a blind actuator the position of the roller blind blind from completely open 0 to completely closed 100 The position of the slider can be controlled via the controls decrease or increase and infinitely variable adjustment via the handle Toggle switch A toggle switch in the app acts like a conventional Switch and has two positions ON and OFF The switch remains in its position until a new ...

Страница 40: ...CBA UP 10 752 Manual english www maintronic com 40 53 Button A button has no fixed position but is only active as long as the button is held ...

Страница 41: ...ction All buttons of the well known switch manufacturers are suitable Function switch The key gears can be individually assigned functions The following steps are necessary Open the Casambi app and select More Open item Switch Choose your maintronic module with keystroke gears Scroll down to the item Button As an example program buttons with single function Controls select a luminaire default Tap ...

Страница 42: ... T2 In the parameter settings of the master the push button mode must be set to Group Button or Group Switch then the keystroke gears T1 T2 of the device react to the group Local single runs via remote switch T1 T2 In the parameter settings of the master the push button mode must be set to Button or Switch then the keystroke gears of the device react directly to the device ...

Страница 43: ...s switch Combine desired devices together in a group Toggle switch Master must be active Select the BLE wireless switch under the Switch function Controls an element here the Up or Down toggle switch of the master must be used Then you have a button for a run Up or Down Proceed the same way for the opposite direction ...

Страница 44: ...d button for the other direction Select a third button as Controls an element and here the toggle switch of the master is used as an element Now you can switch back and forth between individual and group trips with the third button which is configured on the toggle switch Master NOTE Since the BLE wireless buttons have no LED you have no feedback whether the toggle switch Master is currently activ...

Страница 45: ...st be active again at the end of the run To overcome this hurdle several scenes and an animation have to be created as explained by the following example Create a scene for a drive UP or DOWN Create new scene Activate toggle switch for direction and deactivate toggle switch master at the same time By activating the scene the position is driven once up to 100 or 0 it can also not be stopped once th...

Страница 46: ...roceed the same way for the opposite direction NOTE In the case of individual operation with two buttons there is currently the restriction that a fixed position is approached via a scene and cannot be stopped in between Please note for animations with Toggle Switch The scene or animation ends when the drive time expires If animations are used the animation must be at least 1 second shorter than t...

Страница 47: ...om 47 53 7 6 Operation with Device button The device button has the same priority as the Casambi App the last one wins Switching pattern Function LED Relais UP green Relais STOP OFF Relais DOWN red Relais STOP OFF Short press on the device button ...

Страница 48: ...uators are combined as a group one device of the group must be defined as the master For the desired master the push button style must be set to Group Button The other maintronic devices in the group are automatically slaves and the function of the master takes place Switch 3 Function as a switch Press button short drive press button again short stop Release is ignored Group Switch 4 Function as a...

Страница 49: ... also remains in the activated state If a manual drive is started during the day and night timeout the problem occurs that after the timeout has expired it may be automatically driven in the other direction again Explanation A manual drive only remains active until the timeout of the manual control is reached This means that the timeout has elapsed the control falls back to the automation and the ...

Страница 50: ...CBA UP 10 752 Manual english www maintronic com 50 53 ...

Страница 51: ...the set Drive time of the animation 8 2 Unpair devices from network Unpair a device from an existing network A device that is integrated into a Casambi network can be removed from the network again with the function unpair device Ein Gerät dass in ein Casambi Netzwerk eingebunden ist kann über die Funktion Gerät entkoppeln wieder aus dem Netzwerk entfernt werden Devices nearby Select device Unpair...

Страница 52: ...g is disabled In the case that you no longer have access to the network and the security option flick unpairing is disabled the device must be unpaired with the utility app and thus removed from the network Security option flick unpair and allow utility pairing disabled If all network security options such as Allow unpairing Allow flick unpairing and Allow utility unpairing are disabled and you ha...

Страница 53: ...CBA UP 10 752 Manual english www maintronic com 53 53 9 Service and maintenance CBA UP ...

Отзывы: