7.8 Programming timers
A timer needs a scene, to do this, configure as
follows:
Open Casambi app and select a network
Create a scene for a drive
to create a timer go to the menu item
"Timer"
Create new timer > edit > + add Timer
Select start time "Turns ON"
End time "Turns OFF" is not necessary
Add scene
Save timer with "DONE"
Proceed the same way for driving in the
other direction
NOTE
It is to be noted!
If the function "control hierarchy" is to be used, the scene is no longer deactivated after drive time.
The toggle switch also remains in the activated state.
If a manual drive is started during the day and night timeout, the problem occurs that after the timeout has expired, it may
be automatically driven in the other direction again.
Explanation:
A manual drive only remains active until the timeout of the manual control is reached. This means that the timeout has
elapsed, the control falls back to the automation and the blind moves to the position of the set timer.
Ways to work around the control hierarchy issue:
Using fixture buttons or ...
Double click on the device → scroll to "Manual control" → set the parameter to "Timeout, if automation waiting"
program scene with toggle switch
Deactivate scene in THE timer after the desired drive time has elapsed "Turns OFF" (Turns OFF time must be greater than drive
time)