4. Technical data . CBA UP
Specification
CBA UP
Artikel Nr. 10.752
Power supply
130 ... 240V AC 50/60Hz
Switching type
2x interlocked changeover
Switching output
16A
Fuse
External fuse max 10A required
Power consumption
Standby
0,22W
Switch operation
0,77W
Terminals and wiring
Phoenix push-in spring connection
0,5 - 1,5 mm² solid conductor
0,5 - 0,75 mm² fine-stranded conductor with ferrule
Stripping length
9 mm (+/- 0,5 mm)
Controls and indicators
DeviceButton, Status-LED
Protocol
Casambi
App available for Android and IOS
Alternate control
Casambi enabled Push-button inputs
2 x Inputs on mains voltage (L)
Environment
Type of protection
IP20
Protection class
Class II
Temperature ambient ta
0°...+50° Celsius
Temperature critical tc
+70° Celsius
Humidity
5 ... 80% non-condensing (n.c.)
Applied standards
CE
Design
Construction
Flush mounted housing
Mounting
Flush-mounted or junction box
Dimensions (height x width x depth) mm
46,5 x 70(51) x 30
(flaps can be removed)
Ceiling installation
Ø 55mm
Weight
0,070 kg
Housing
Ultramid flame resistant, black
Customs
HS-Code/ TARIC-Number
85365080
Country of origin
Germany