11 Final mounting
20
Maximum length of power supply cable in the housing is 7 cm.
Cut off and insulate PE conductor and individual cable cores that are not required
Nominal load can be
switched without
base load
Nominal load can be
switched with permanent
base load
Nominal load and
base load can be
switched
Please tick the connection variant
11 Final mounting
NOTICE Malfunction in case of incorrect in-
stallation.
For installation conditions and detailed informa-
tion on the final assembly of the fan insert and
cover → Observe
Instructions for ER covers
.
11.1 Attaching fan insert
1. Plug the fan insert directly into the 3 studs in
the interior of the surface-mounted housing.
2. Fasten with the 3 supplied screws (4x10). Do
not over-tighten screws.
3. Check for firm seating of the fan insert.
11.2 Attaching cover ER-A, ER-AK,
ER-AH or ER-AB
1. Screw cover to the fan insert with the central
screw.
The covers ER-AK, ER-AH and ER-AB are
electrically connected automatically when
installed. The setting values can be changed
on these covers.