8. Wireless components – Setting up and deleting │ UK
31
Wireless window contact
1. Activate set-up mode on the fan.
> LED flashes, set-up mode is active.
2. Press window contact set-up button.
> If set-up is successful the LED will light
up for about 1 second.
Deleting individual transmitters
In order to delete the required transmitter, the
transmitter teaching process (RLS RC, radio
switch or window contact) has to be repeated
(
Chapter 8.3.1 to 8.3.4).
Deleting all transmitters
1. Activate set-up mode on the fan.
> LED flashes, set-up mode is active.
2. Press the set-up button [11] briefly twice.
> LED flashes briefly twice and then goes
out.
3. Press and hold the teaching button [11] at
the fan (> 2 seconds), until the LED on the
fan lights up briefly once.
> All taught-in transmitters are deleted.
The fan is again in its initial state.
Setting up master and slave fan(s)
1. Activate set-up mode on the master fan
and another fan that has not been set up
yet.
> LED flashes, set-up mode is active.
2. On the slave fan, briefly press the set-up
button once. LED on slave lights up briefly
and then flashes briefly once. > Slave fan
is in transmit mode.
3. Press the set-up button on the slave fan
for at least 2 seconds until the LED on the
slave fan briefly lights up once.
> At the same time the flashing LED on
the master fan will light up briefly once
and then go out.
The set-up process was successful. If the set-
up process fails, the LED on the slave fan
flashes briefly 3 times and the process must
be repeated.
Deleting a slave fan
Repeat procedure according to "Setting up
master and slave fan(s)" chapter.
Set up fan as repeater
Settings:
Off, level 1 (original telegrams
repeated) or level 2 (original and previously
repeated telegrams are repeated).
To use the radio electronic unit in the fan
to repeat EnOcean telegrams, proceed as
follows:
1. Activate set-up mode on the fan.
> LED flashes, set-up mode is active.
2. Press the set-up button [11] briefly 3 times.
LED lights up briefly and then flashes
briefly 3 times.
3. For repeater mode, briefly press set-up
button [11]
x times
:
Off
once
LED flashes once
Level 1
twice
LED flashes twice
Level 2
3 times
LED flashes 3 times
4. Hold down the set-up button (> 1 second)
until the LED on the fan lights up once
(for about 1 second). The setting is stored.
9. Operation
ECA 150 ipro, ECA 150 ipro K
The unit is switched on and off with a switch to
be provided by the customer (double rocker
switch for 2-level operation). With an on/off
switch the unit can also be operated only at
the high performance level or only at the low
performance level (200 m³/h or 250 m³/h).
ECA 150 ipro VZC, ECA 150 ipro KVZC
The unit is switched on and off with a switch
to be provided by the customer. It is then
operated with the set start delay and overrun
time as defined by one of 4 operating
programs (Comfort, Demand, Save or Power
Chapter 7.2.1). The sequence of perfor-
mance levels is determined in the operating
program.
Содержание ECA 150 ipro