UK │ 3. Environmental conditions and operating limits
24
3. Environmental conditions and
operating limits
● Permissible maximum temperature of air
40 °C.
● The domestic air supply must be set up so
that no air can flow into the living areas
from the kitchen, bathroom and WC.
● There must be a sufficient supply of fresh
air within the apartment. Overflow vents
which cannot be closed should be installed
for this purpose.
● Sufficient supply air intake must be ensured
during operation with air-ventilated firepla-
ces. The maximum permitted pressure
difference per living unit is 4 Pa.
● All units have resistance to interference
according to EN 55014-2 (1000 to 4000 V
depending on pulse shape and energy
component). If operating with fluorescent
tubes, these values may be exceeded. In
this case, additional interference
suppression measures (L, C components
or RC module, protection diodes,
varistors) are required.
4. Technical data
For technical data
rating plate [S1] or
[S2.1]/[S2.2]. For dimensions and character-
ristic curves refer to:
catalogue or website
(maico-ventilatoren.com or scan QR code
on fold-out side).
Models B and KB (motion sensors)
Range
5 m
Detection range:
● horizontal
● vertical
100°
82°
Wireless models RC, RCH, KRC, KRCH
Wireless components:
Frequency range
(in accordance with EN 300220-1)
868.35
MHz
Range inside building,
depending on building fabric
● Room air control
RLS RC
Fan
● Radio switch DS RC
Fan
● Fan
Fan
● Repeater
Fan
up to:
30 m
30 m
30 m
40 m
5. Safety instructions and
warnings
CAUTION
Indicates a possibly dangerous
situation, which could result in
minor to moderate injuries.
NOTICE
Indicates a possible situation,
which could cause damage to
the product or its surroundings.
The fan unit
must not
be used in the follo-
wing situations
under any circumstances.
Risk of combustion/fire from flam-
mable materials, liquids or gases in
the vicinity of the fan.
Do not place
any flammable materials, liquids or gases
near the fan, which may ignite in the event of
heat or sparks and catch fire.
Explosive gases and dusts may
ignite and cause serious explosions
or fire.
Never use fan unit in an
explosive atmosphere (risk of explosion).
Risk from operating in single air
extraction systems in accordance
with DIN 18017-3
. Fan does not satisfy
the DIN 18017-3 standard. Do not use fan in
systems in accordance with DIN 18017-3.
Risk to health from chemicals or
aggressive gases/vapours.
Chemicals or aggressive
gases/vapours may harm health, especially
if they are distributed throughout the rooms
by the fan. Never use fan to convey
chemicals or aggressive gases/vapours.
Grease and oil vapours from range
hoods may contaminate the fan and
ventilation ducts and reduce
efficiency.
Never use fan to convey greasy
air, e.g. in combination with range hoods
with exhaust air operation.