4.  Maintenance

4.1 

Maintenance interval

Description

Action

Frequency

Filter elements 

(Water, oil, carbon)

Replace

Yearly  or  when  indicator  on  the  filter 

head  moves  to  the  CHANGE  area  as 

shown in Fig. 11.

Automatic drain

Clean

When required.

Fig. 11:  Filter life indicator

 

m

Never perform any maintenance work which is not expressly 
recommended in this section.

 

m

Contact customer service if components have to be replaced 
other than in the course of maintenance work.

4.2 

Automatic water/oil drain

4.2.1  Checking functionality

 

t

A periodic check of the automatic drains is necessary to en-
sure maximum membrane life.

To verify float is functioning correctly:

1. 

Open  the  filter  bowl  by  turnign  one-quarter  turn  counter-
clockwise.

2. 

Inspect inside of filter housing for water or oil.

3. 

If a float is not functioning, it may be submerged in water/oil.

 

t

If a float is found to be inactive, follow the cleaning procedure.

 

t

If necessary, a replacement drain is available for purchase. 
MSS P/N 026 80386 00.

4.2.2  Cleaning automatic drain

Fig. 12:  Automatic drain disassembly

1  Filter bowl
2  Float housing
3  Needle
4  Float seat
5  O-ring
6  Retention nut

To clean the automatic drains:

1. 

Turn the filter bowl (Fig. 12, Pos. 1) counter clockwise one-
eighth turn and pull the filter bowl down from the filter housing.

2. 

Unscrew the nut (Fig. 12, Pos. 6). 

3. 

Remove the drain unit (Fig. 12, Pos. 2-5) from the filter bowl 
(Fig. 12, Pos. 1).

4. 

Remove the o-ring (Fig. 12, Pos. 5). 

5. 

Carefully pull the float housing (Fig. 12, Pos. 2) from the seat 
(Fig. 12, Pos. 4). Do not bend the needle (Fig. 12, Pos. 3).

6. 

Clean the parts with soap and water. Make sure the needle 
bore is open and clean.

7. 

Assemble the parts in the reverse order. Make sure the parts 
are dry before reassembly.

Содержание NitroPRO NTF-515B

Страница 1: ...MAHLE NTF 515B EN Operation Manual Nitrogen Tire Filling Unit...

Страница 2: ...fill accessory connection port 11 2 6 Functional description 12 2 6 1 Unit function 12 2 6 2 Nitrogen generation 12 2 7 Commissioning 13 2 7 1 Removing transportation packaging 13 2 7 2 Verify air sou...

Страница 3: ...MAHLE 3 en...

Страница 4: ...erating MAHLE products it is absolutely essential that the Original instructions owner s manual and in particular the safety instructions are studied carefully By doing so you can eliminate any uncert...

Страница 5: ...haser to operate and maintain MSS equipment according to instructions in the MSS Operation Manual for the covered product MSS provides free technical support over toll free telephone lines in the USA...

Страница 6: ...instructions or normal operating procedure d Any damage to product during original shipment or subse quent shipments to MSS s facility for service e Portions of products which are subject to warrantie...

Страница 7: ...ts and other contaminants Do not place the NTF 515B in a room where organic solvent vapors may be present y y Oil content of the compressed air should be less than 0 01mg m3 y y Ensure that the compre...

Страница 8: ...essed air not exceeding 150 PSI Excess pressure could damage mem brane and other internal components m mCheck filters daily prior to use to ensure clean dry air is being fed to the membrane Damage may...

Страница 9: ...5 or 98 8 Oil filter with automatic drain 9 Nitrogen membrane Fig 3 Front control panel 1 Air inlet pressure gauge 2 Power switch 3 Main display LCD 4 Tank pressure LCD 5 button 6 button 7 START butto...

Страница 10: ...and release silver clip N N To remove the air chuck from the valve stem press down on the silver clip and pull off of valve stem Fig 6 Air chuck 2 4 User interface 2 4 1 Selection and function keys K...

Страница 11: ...NTF 515B can be prevented by locking the caster brakes Fig 1 Pos 5 at the rear wheels 2 5 5 Battery and battery charger The NTF 515B is powered by a 12V 7AH battery mounted inside the cabinet There is...

Страница 12: ...or exit and the NTF 515B inlet so that the hot compressed gas has time to cool within the specifications listed in this manual A higher membrane pressure will increase the capacity i e nitrogen output...

Страница 13: ...temperature is below 110 F m mIf your application requires an inlet pressure of 100 119PSI the pressure value can be adjusted to accomodate the lower system pressure Contact MSS Technical Support at...

Страница 14: ...etween the gauge reading and the display 3 1 1 Over pressure setting OPS and nitrogen purge cycles N2P The Over Pressure Setting can be used to improve the nitrogen purity in the tire s The Over Press...

Страница 15: ...2321 3 5 Nitrogen purge cycle N N Process can be used for single or multiple tires 1 Attach air supply 150PSI max to the NTF 515B 2 Turn on POWER switch PCB will display battery charge status HI or L...

Страница 16: ...of filter housing for water or oil 3 If a float is not functioning it may be submerged in water oil N N If a float is found to be inactive follow the cleaning procedure N N If necessary a replacement...

Страница 17: ...the filter housing Fig 13 Pos 1 5 Unscrew the blue knob Fig 13 Pos 4 6 Remove the old filter element Fig 13 Pos 3 7 Clean the sieve Fig 13 Pos 2 filter bowl and the filter housing if necessary 8 Insta...

Страница 18: ...355 80094 00 Service hose assembly 24ft 355 80095 00 Battery charger power cord 025 80436 00 Battery charger 026 80636 00 Battery charger and cord 355 80204 00 Battery 12VDC 040 80220 00 Automatic dra...

Страница 19: ...MAHLE Notes 19 en 5 Notes...

Страница 20: ...2017 09 21 035 82548 00 MAHLE Aftermarket Inc 10 Innovation Drive York PA 17402 USA 717 840 0678 www servicesolutions mahle com...

Отзывы: