background image

© MAHLE 

Information  |  NTF-515B  |  7

NTF-515B  |  7

  |  7

en

1.4 

Safety regulations

1.4.1  NTF-515B

Always carefully study and follow all the safety regulationsbefore 
using the MAHLE product. Correct use of the NTF-515B is im-
portant for your personal saftey and for trouble-free functionality. 
Incorrect use can cause damage to the unit or lead to incorrect 
functionality.

Nitrogen can cause suffocation. Make sure there is 
adequate ventilation at all times!

 

y

Regular maintenance should be performed on the NTF-515B 
to  ensure  proper  and  safe  operation.  Ensure  that  instruc-
tions concerning health and safety are compliant with local 
regulations.

 

y

Some  shop  air  supplies  have  an  oiler  installed  to  provide 
lubrication to air tools. The life of the NTF-515B filters will be 
increased if the air supply is free of moisture and oil.

 

y

Only supply the NTF-515B with compressed air.

Oxygen enriched air leads to increased risk of fire in 
the event of contact with flammable products.

 

y

Do not block the flow of air from the membrane vent. Dam-
age may occur.

 

y

Always follow vehicle manufacturer's suggested tire inflation 
pressure.

 

y

Incorrect settings on the NTF-515B can allow overinflation of 
tires leading to a possible bursting of the tire.

 

y

Do not install the NTF-515B in an area where explosive sub-
stances may be present.

Ensure the feed air pressure cannot exceed 150PSI.

 

y

Keep  ambient  air  temperature  between  40˚F  -  110˚F  (5˚C  - 
43˚C).  Do  not  connect  hot  compressed  air  directly  from  a 
compressor to inlet of the NTF-515B.

 

y

Keep air feed to the NTF-515B clean and free of vapors of 
organic solvents and other contaminants. Do not place the 
NTF-515B in a room where organic solvent vapors may be 
present.

 

y

Oil content of the compressed air should be less than 0.01mg/
m

3

.

 

y

Ensure that the compressed air pressure and quality is always 
as prescribed.

 

y

Ensure  air  supply  is  rated  for  100-150PSI  and  minimum 
13.3CFM.

 

y

The NTF-515B unit should not be exposed to excess moisture 
or be operated in wet areas.

In the case of an emergency, turn off power switch 
and disconnect the compressed air supply line quick 
coupling.

 

y

The  NTF-515B  can  be  secured  in  position  by  locking  the 
caster brake.

 

y

There  are  no  additional  safety  systems  for  protecting  the 
NTF-515B  against  damage  resulting  from  natural  catastro-
phes.

 

y

Never  remove  any  components  from  inside  the  NTF-515B 
except for maintenance or repair purposes.

 

y

Follow the pertinent legal regulations or directives to ensure 
safe handling of pressurized devices.

 

y

The NTF-515B must be subjected to regular maintenance by 
service personnel or authorized agents to ensure the safety 
of the unit.

 

y

Never perform any maintenance work which is not expressly 
recommended  in  this  manual.  Contact  customer  service  if 
components have to be replaced other than in the course of 
maintenance work.

 

y

If there is damage to the NTF-515B, terminate usage imme-
diately and contact customer service.

 

y

The service hoses and service quick-release couplings must 
be regularly checked for wear and replaced if damaged.

 

y

Observe local laws or directives as to ensure the safety of the 
pressurized device.

1.5 

Technical data

Feature

Value/Range

Dimensions H x W x D

1250 x 510 x 560mm

Weight

108kg

Unit operating voltage

12VDC

Battery charger voltage

110/220VAC

Air supply

100-150PSI, 13.3 CFM

Storage tank capacity

15gal

Содержание NitroPRO NTF-515B

Страница 1: ...MAHLE NTF 515B EN Operation Manual Nitrogen Tire Filling Unit...

Страница 2: ...fill accessory connection port 11 2 6 Functional description 12 2 6 1 Unit function 12 2 6 2 Nitrogen generation 12 2 7 Commissioning 13 2 7 1 Removing transportation packaging 13 2 7 2 Verify air sou...

Страница 3: ...MAHLE 3 en...

Страница 4: ...erating MAHLE products it is absolutely essential that the Original instructions owner s manual and in particular the safety instructions are studied carefully By doing so you can eliminate any uncert...

Страница 5: ...haser to operate and maintain MSS equipment according to instructions in the MSS Operation Manual for the covered product MSS provides free technical support over toll free telephone lines in the USA...

Страница 6: ...instructions or normal operating procedure d Any damage to product during original shipment or subse quent shipments to MSS s facility for service e Portions of products which are subject to warrantie...

Страница 7: ...ts and other contaminants Do not place the NTF 515B in a room where organic solvent vapors may be present y y Oil content of the compressed air should be less than 0 01mg m3 y y Ensure that the compre...

Страница 8: ...essed air not exceeding 150 PSI Excess pressure could damage mem brane and other internal components m mCheck filters daily prior to use to ensure clean dry air is being fed to the membrane Damage may...

Страница 9: ...5 or 98 8 Oil filter with automatic drain 9 Nitrogen membrane Fig 3 Front control panel 1 Air inlet pressure gauge 2 Power switch 3 Main display LCD 4 Tank pressure LCD 5 button 6 button 7 START butto...

Страница 10: ...and release silver clip N N To remove the air chuck from the valve stem press down on the silver clip and pull off of valve stem Fig 6 Air chuck 2 4 User interface 2 4 1 Selection and function keys K...

Страница 11: ...NTF 515B can be prevented by locking the caster brakes Fig 1 Pos 5 at the rear wheels 2 5 5 Battery and battery charger The NTF 515B is powered by a 12V 7AH battery mounted inside the cabinet There is...

Страница 12: ...or exit and the NTF 515B inlet so that the hot compressed gas has time to cool within the specifications listed in this manual A higher membrane pressure will increase the capacity i e nitrogen output...

Страница 13: ...temperature is below 110 F m mIf your application requires an inlet pressure of 100 119PSI the pressure value can be adjusted to accomodate the lower system pressure Contact MSS Technical Support at...

Страница 14: ...etween the gauge reading and the display 3 1 1 Over pressure setting OPS and nitrogen purge cycles N2P The Over Pressure Setting can be used to improve the nitrogen purity in the tire s The Over Press...

Страница 15: ...2321 3 5 Nitrogen purge cycle N N Process can be used for single or multiple tires 1 Attach air supply 150PSI max to the NTF 515B 2 Turn on POWER switch PCB will display battery charge status HI or L...

Страница 16: ...of filter housing for water or oil 3 If a float is not functioning it may be submerged in water oil N N If a float is found to be inactive follow the cleaning procedure N N If necessary a replacement...

Страница 17: ...the filter housing Fig 13 Pos 1 5 Unscrew the blue knob Fig 13 Pos 4 6 Remove the old filter element Fig 13 Pos 3 7 Clean the sieve Fig 13 Pos 2 filter bowl and the filter housing if necessary 8 Insta...

Страница 18: ...355 80094 00 Service hose assembly 24ft 355 80095 00 Battery charger power cord 025 80436 00 Battery charger 026 80636 00 Battery charger and cord 355 80204 00 Battery 12VDC 040 80220 00 Automatic dra...

Страница 19: ...MAHLE Notes 19 en 5 Notes...

Страница 20: ...2017 09 21 035 82548 00 MAHLE Aftermarket Inc 10 Innovation Drive York PA 17402 USA 717 840 0678 www servicesolutions mahle com...

Отзывы: