background image

© MAHLE 

30  |  ACX2120H  |  Maintenance forms

en

14.

 

Maintenance

14.1

 

Vacuum pump oil change

Vacuum pump oil change record

Date

Maintenance t

Maint. tech. signature and stamp

Содержание ArcticPRO ACX2120H

Страница 1: ...EN Operation manual A C Service Equipment MAHLE ACX2120H...

Страница 2: ...5 Equipment installation 13 5 1 Unpacking ACX2120H 13 5 2 Load cell screw release 13 6 Commissioning 14 6 1 Connections and positioning 14 6 2 First start up veri cation 14 7 Setup 15 7 1 ACX2120H 15...

Страница 3: ...1 Multipass 24 10 12 System info 24 10 13 Software update 25 10 14 Refrigerant weight accuracy check 25 10 15 Printer maintenance 26 10 16 Periodic checks 26 11 27 12 27 12 1 A C Service unit disposal...

Страница 4: ...tective goggles X Wear protective gloves 2 Important notes Beforestartup connectingandoperatingMAHLE products it is absolutely essential that the Original instructions owner smanualand inparticular th...

Страница 5: ...towards making to work in are carried out Electrical engineering in Germany is subject to the accident prevention regulations of the trade association Electrical Plant and Equipment as under BGV A3 pr...

Страница 6: ...becontaminatedwithmoisture lubricant dirtandtraces of other gases If the refrigerant has been contaminated by being mixed with other gases remove the contaminated refrigerant and add fresh R134a befor...

Страница 7: ...ice if components have to be replaced other than in the course of maintenance work ACX2120Hmustbeconnectedtoaproperlygroundedelectri cal connection If there is damage to the ACX2120H terminate usage i...

Страница 8: ...e ACX2120H can only be operated with R134a The ACX2120H is not to be used for service work on vehicles with air conditioning systems employing refrigerants other than R134a as this will cause damage P...

Страница 9: ...Locking Caster 9 Rear Wheel 10 Used Oil Bottle 11 Printer optional 1 2 3 4 1 1 2 3 5 4 2 Fig 2 Rear View 1 Service Hoses 2 Fan 3 Vent 4 Hose Storage Fig B USB Ports 1 USB Type B device port to PC 2 US...

Страница 10: ...ice functions are available in the pages shown on the LCD display Data entry and moving of the cursor is controlled by the keypad The LCD displays the service equipment s status the progress of A C sy...

Страница 11: ...coLOCK is the intelligent coupler that with the suitable auto mated procedure in the software enables to reduce the amount of non condensible gases formed inside the cylinder avoid the refrigerant los...

Страница 12: ...t 22lbs Method to weigh gas content Load cell Recovered oil container 250ml Vacuum pump 2CFM dual stage Vacuum pump oil quantity 250ml Compressor capacity 0 87cu in 14cc Dr ter 75kg of recovered R134a...

Страница 13: ...ps and remove the carton Fig 9 Fig 9 Removing carton 2 Cut straps securing unit to pallet 3 With 2 people lift both front wheels by levering with the handle so unit is setting on the rear wheels Fig 1...

Страница 14: ...tive gloves Executethefollowingactionsinsequentialorderbyfollowingthe procedure as shown on the display Gas weight check vacuums entire refrigerant circuit to ensure no contaminants are in system prio...

Страница 15: ...E is highlighted and press 2 Adjust whether the Recharge mode is in Quick mode or Zero tolerance by pressing If Zero Tolerance mode is selected press to highlight the pressure and use to adjust the va...

Страница 16: ...t SAVE then press to save selection 4 Unit will restart upon saving the language selection m If a language is selected that is not understood simply switch unit depress enter key and turn unit back on...

Страница 17: ...e used for air conditioning systems repaired using a chemical sealant Non compliance will void the warranty m Neverattempttoclosethevalvesoftheinternalrefrigerantbottle while the ACX2120H is in operat...

Страница 18: ...lection and move to next parameter The following options are available HP only LP only HP and LP HP LP Injection through HP hose on the system low pressur t Third row of information displays the vacuu...

Страница 19: ...misempty operatormustexitandselectavacuumprocess m There is potential for unit to display an error during this service for high internal pressure This can occur due to high operating temperatures or h...

Страница 20: ...instructions 9 2 5 Pressure check t This process is used to check the pressure inside the vehi cle s A C system using the ACX2120H 1 Connect HP LP couplers to the vehicle A C system 2 Follow on screen...

Страница 21: ...e goggles X Wear protective gloves t Before the ACX2120H can be used the internal refrigerant cylinder must be with liquid refrigerant Use only R134a refrigerant t The refrigerant can be obtained from...

Страница 22: ...until CYLINDER REFRIGERANT VIEW is highlighted and press 2 Screen will display the Total refrigerant weight and the Avail able refrigerant weight Fig 25 Refrigerant weight screen t Available refriger...

Страница 23: ...Long life pump screen 10 9 Vacuum pump oil change t After 60 hours of runtime or 1000 hours if the Long Life Pump test is completed successfully the vacuum pump oil must be replaced 1 Disconnect ACX2...

Страница 24: ...ect the HP and LP couplers and hoses and allow the hose drain process to run to completion 4 Disconnect Turn front locking latch using a flathead screwdriver and carefully open the front housing ACX21...

Страница 25: ...power cord to power supply and switch on unit 4 From the MAINTENANCE menu press until REFRIG Erant weight accuracy check is highlighted and press 5 Press YES tocontinuewhenthescreeninFig 34appears Fig...

Страница 26: ...peration Make sure no corrosion or leakage is present in the in ternal cylinder and other metallic parts of the equipment under normal conditions the internal cylinder life is at least 20 years If aut...

Страница 27: ...or by its reseller Con tact technical support for replacement parts not listed above 12 Disposal 12 A C Service unit disposal 12 2 Recycled material disposal 12 3 Packaging disposal At the end of its...

Страница 28: ...ting an external suitable tank with safety valve W032 NO PRESSURE VEHICLE WITHOUT REFRIGERANT OR DISCONNECTED During the refrigerant recovery phase Hoses not connected Couplers not opened Check connec...

Страница 29: ...the internal tank Check calibration and calibrate if necessary A037 FURTHER REFRIG ERANT INJECTION NOT POSSIBLE During gas injection phase Hoses not connected to vehicle A C system Couplers closed Va...

Страница 30: ...MAHLE 30 ACX2120H Maintenance forms en 14 Maintenance 14 1 Vacuum pump oil change Vacuum pump oil change record Date Maintenance t Maint tech signature and stamp...

Страница 31: ...MAHLE Maintenance forms ACX2120H 31 en Vacuum pump oil change record Date Maintenance technician identification Maint tech signature and stamp...

Страница 32: ...MAHLE 32 ACX2120H Maintenance forms en 14 2 Filter dryer change Filter Dryer Change Record Date Maintenance t Maint tech signature and stamp...

Страница 33: ...MAHLE Maintenance forms ACX2120H 33 en Filter Dryer Change Record Date Maintenance technician identification Maint tech signature and stamp...

Страница 34: ...MAHLE 34 ACX2120H Maintenance forms en Filter Dryer Change Record Date Maintenance technician identification Maint tech signature and stamp...

Страница 35: ...LE Maintenance forms ACX2120H 35 en 14 3 Refrigerant load cell calibration check Refrigerant Load Cell Calibration Check Record Date Result of check pass fail Maintenance t Maint tech signature and st...

Страница 36: ...MAHLE 36 ACX2120H Maintenance forms en Refrigerant Load Cell Calibration Check Record Date Result of check pass fail Maintenance technician identification Maint tech signature and stamp...

Страница 37: ...MAHLE Maintenance forms ACX2120H 37 en 14 4 Other checks maintenance repairs Filter Dryer Change Record Job Date Result of check pass fail Maintenance t Maint tech signature and stamp...

Страница 38: ...MAHLE 38 ACX2120H Maintenance forms en Filter Dryer Change Record Job Date Result of check pass fail Maintenance technician identification Maint tech signature and stamp...

Страница 39: ...MAHLE Notes ACX2120H 39 en 15 Notes...

Страница 40: ...2019 03 04 035 82681 00 REV A MAHLE Aftermarket Inc Service Solutions 10 Innovation Drive York PA 17402 USA 717 840 0678 www servicesolutions mahle com...