© MAHLE
Setup | ACX2120H | 15
en
7.
Setup
7.1
ACX2120H
t
From the SETUP menu, it is possible to enable/disable and
set certain parameters prior to performing A/C system service.
To access SETUP from the main menu, press
ª©
to highlight
SETUP and then press
.
Parameter
Description
EcoLOCK
Enable/disable EcoLOCK functionality
Recharge mode
Select Quick mode or Zero tolerance recharge method
Pressure check
Enable/disable the pressure check
Multipass
Enable/disable the Multipass function
Report saving
mode
Adjust what reports are saved during A/C service
Unit of measure
Modify the unit of measure for pressure and weight
Clock adjustment
Modify the date and time
Language
Modify the language displayed on the unit LCD display
Startup screen
Select if upon power-up the unit displays the database
page or main menu screen
Default setup
Restore unit default settings
t
If while adjusting settings user does not want to apply any
change made, just press
ESC
from the parameter screen to
discard the change made t
rea.
7.1.1
Ecolock (optional)
Ecolock
1.
From the
SETUP
menu,
press
ª©
until
is high -
lighted and press
.
2.
Adjust whether the EcoLOCK function is enabled or disabled
by pressing
§¨
.
3.
Press
ª
to highlight
SAVE
, then press
to save selection.
7.1.2
Recharge mode
t
For a more detailed description of the 2 charge modes, see
Section 8.3.
1.
From the
SETUP
menu,
press
ª©
until
RECHARGE MODE
is highlighted and press
.
2.
Adjust whether the Recharge mode is in
Quick mode
or
Zero tolerance
by pressing
§¨
. (If Zero Tolerance mode is
selected, press
ª
to highlight the pressure and use
§¨
to
adjust the value.)
3.
Press
ª
to highlight
SAVE
, then press
to save selection.
7.1.3
Pressure check
1.
From the
SETUP
menu,
press
ª©
until
PRESSURE CHECK
is highlighted and press
.
2.
Adjust whether the Pressure check function is enabled or
disabled by pressing
§¨
.
3.
Press
ª
to highlight
SAVE
, then press
to save selection.
7.1.4
Multipass
t
Multipass
is a function user can enable that will run when
unit is powered up and in an idle state. This function circu -
lates the refrigerant from the internal cylinder through the
ters to ensure optimal purity.
1.
From the
SETUP
menu,
press
ª©
until
MULTIPASS
is high -
lighted and press
.
2.
Adjust whether the Multipass function is enabled or disabled.
3.
Press
ª
to highlight
SAVE
, then press
to save selection.
7.1.5
Report saving mode
1.
From the
SETUP
menu,
press
ª©
until
REPORT SAVING
MODE
is highlighted and press
.
2.
Adjust whether all cycle reports, automatic cycles only or no
reports are saved by pressing
§¨
.
3.
Press
ª
to highlight
SAVE
, then press
to save selection.
7.1.6
Unit of measure
1.
From the
SETUP
menu, press
ª©
until
UNIT OF MEASURE
is highlighted and press
.
2.
Use
ª©
to select if Pressure or Gas units are to be adjust -
ed, then press
.
3.
Adjust the units by pressing
§¨
.
4.
Press
ª
to highlight
SAVE
, then press
to save selection.
5.
If other units are to be adjusted, press
ª©
to select other
parameter or press
ª
to highlight
SAVE
, then press
to save
any changes.
Содержание ArcticPRO ACX2120H
Страница 1: ...EN Operation manual A C Service Equipment MAHLE ACX2120H...
Страница 39: ...MAHLE Notes ACX2120H 39 en 15 Notes...