© MAHLE
28 | ACX2120H | Troubleshooting
en
13.
Troubleshooting
t
Please contact technical service if any of the actions suggested in this section cannot be implemented.
t
Notice/Warning codes are coded
Wxxx
on the title of the window.
t
Alarm codes are coded
Axxx
on the title of the window - alarms terminate procedure and prevent its resumption.
13.1
ACX2120H
Error code
Messages
When it occurs
Possible solutions
Action
W008
REPLACE VACUUM
PUMP OIL
– When required after Pump Monitor -
ing system procedure
– Pump oil contaminated
– Replace pump oil
W009
REPLACE DRYER
FILTER
– Every year since installation
– Filt
– Replace dr
ter
W025
REFRIGERANT
QUANTITY TOO
HIGH
– During the programming of the in -
ner tank charge amount
– Amount required greater than that
available in internal tank
– Decrease the set quantity.
W026
RECHARGE CYL
-
INDER EMPTY OR
DISCONNECTED
–
– Recharging tank empty
– Hoses/couplings are clogged/
closed
– Check tank, hoses, taps.
W029
CYLINDER NEAR
-
LY FULL
– During the refrigerant recovery or
hoses emptying phase.
– Tank close to maximum capacity
– Decr
(injecting) an external suitable tank
(with safety valve)
W032
NO PRESSURE -
VEHICLE WITHOUT
REFRIGERANT OR
DISCONNECTED
– During the refrigerant recovery
phase
– Hoses not connected
– Couplers not opened
– Check connections and leaks in
A/C system
W044
CYLINDER EMPTY
–
Tank refrigerant
internal recycling phase
– Gas level is too low for the proce
-
dure to be completed
– Fill the internal tank with gas
W045
LP VERY LOW,
CHECK CIRCUIT
BEFORE CONTIN
-
UING
–
– LP hose disconnected
– Flushing couplings not properly
connected
– Leak in cir
–
and eliminate any leaks.
W047
POSSIBLE LEAK
-
AGE
– During the refrigerant recovery
phase
– Vehicle A/C system may have leaks
– Inspect vehicle A/C system and re
-
pair
A000
EEPROM NOT
WORKING
– Electronics fault
– EEPROM damaged
– Replace the logic electronic board
A001
EEPROM DATA
CORRUPT
– Electronics fault
– EEPROM damaged
– Replace the logic electronic board
A002
PRESSURE SAFE
-
TY SWITCH ACTI
-
VATED
– Pressure above 18 bar
– High pressure in the internal tank
– Circuit between compressor and
tank obstructed or closed
Verify:
– If internal CYLINDER pressure lev
-
el is over 18 bar, wait for pressure
reduction, disconnect equipment
from the mains, use safety protec
-
tion
– Open equipment and verify if the
valve between compressor and in
-
ternal CYLINDER are open
Содержание ArcticPRO ACX2120H