| ACX380/480 | 36 en
APPENDIX 3 – ACX380/480 - ELECTRICAL CONNECTION – LOGIC
ELECTRONIC BOARD
Item
label
Description
Connected ( ) Unused (x)
1)
FAN
Tachometric fan connector
2)
SER I/O
serial I/O interface to power board
3)
PAR I/O
parallel I/O interface (not used)
X
4)
SER AUX
refrigerant gas identifier serial interface
optional
5)
PRN
thermal printer serial interface (power and communication)
6)
LC Tank
input load cell tank
7)
LC Dye2
input load cell dye 2
X
8)
LC New
Oil2
input load cell new oil 2
9)
LC Dye1
input load cell dye 1
10)
LC New
Oil1
input load cell new oil 1
11)
PS Tank
input pressure sensor tank
12)
LC Ex.Oil
input load cell
13)
PS LP
input pressure sensor LP
14)
PS HP
input pressure sensor HP
15)
TS Tank
input temperature sensor refrigerant tank/cylinder
X
16)
TPSW 1
input anti-tamper switch
X
17)
TPSW 2
input anti-tamper switch
X
18)
TPSW 3
input anti-tamper switch
X
19)
USB0 = USB port for BSP programming of MCU (only for production operations)
X
20)
PCAP
LCD touch screen interface
21)
KYB
matrix keyboard interface
X
22)
Lithium RTC battery CR2032 3V
23)
USB Service (only for production operations)
X
24)
Recovery button = programming BSP of MCU
25)
LCD
LCD interface
26)
BKL
LCD backlight supply connector
Содержание ACX380
Страница 1: ...MAHLE ACX380 480 EN Service Manual A C Service Equipment...
Страница 31: ...en 31 ACX380 480 APPENDIX 1 REFRIGERANT FLUID CIRCUIT ACX380 480 H...
Страница 32: ...ACX380 480 32 en APPENDIX 2 REFRIGERANT FLUID CIRCUIT ACX380 480 OPERATIONAL CYCLES Uncondensable gases H...
Страница 33: ...en 33 ACX380 480 Recovery cycle H...
Страница 34: ...ACX380 480 34 en Vacuum H...
Страница 35: ...en 35 ACX380 480 Recharge H...
Страница 45: ...MAHLE Aftermarket Italy S p A Via Quasimodo 4 a 43126 Par ma ITALY 2019 10 28...