STEP 3 – CHECK UICU POWER AND GROUND CIRCUIT
PRE CONDITION
• Turn ON ignition
TEST PROCEDURE
•
Check the UICU power and ground wires
ACCEPTANCE CRITERIA
• Is the power and ground circuit of UICU is OK
ACTION TO BE TAKEN
OK
NOT OK
• Connect i-SMART and try to clear all DTC’s
• If the DTC’s not getting cleared,
Contact
TEKliner for further assistance
• If the DTC’s got cleared. Turn OFF the ignition,
wait for 2 minutes. Turn ON ignition & Check
whether the issue is resolved
• Replace or repair the wiring harness
• After replacing the wiring harness,
Check
whether
the
DTC
got
reproduced.
• If the DTC reproduced again, contact
TEKline