![MAHA VZM 300 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/maha/vzm-300/vzm-300_original-operating-instructions_3666843029.webp)
Trigger Menu
VZM 300
D1 2010BA0-GB03
4.3
4.2
Start Deceleration Measurement / Activate Triggers
The automatic START trigger threshold will be prompted on the display.
Select using <0> or <1>.
Use <ENTER> to take over the setting and continue with
the measurement.
/)$g" "(gHKI
Q9RQ8RMR
Depending on the selector switch configuration, the measurement can either be started
automatically by the trigger thresholds of the brake deceleration or of the external sensors, or
manually with the <ENTER> key or the hand trigger.
4.3
Terminate Deceleration Measurement / Deactivate Triggers
The next display prompts for the automatic STOP trigger threshold.
Select using <0> or <1>.
Use <ENTER> to take over the setting and continue with
the measurement.
/)$g" "(gHMI
Q9RQ8RMR
After the vehicle has come to a full stop, the measurement can either be terminated
automatically by the trigger thresholds of the sensors or manually by the hand trigger.
If the maximum measuring time has been exceeded, the measurement will be terminated
automatically before the vehicle has come to a full stop.
Then the display prompts for the automatic START/STOP trigger thresholds for:
Pedal
force
Tractive
force
Pressure sensor 1
Pressure sensor 2
Pressure sensor 3
Use <
Í
> or <
Î
> to page through the menu items.
Summary / Sequence of the sensor selection for the measurement start/stop
1. Pressure sensor 2 available?
2. Pressure sensor 3 available?
3. Trigger threshold of brake deceleration for automatic start of measurement
4. Trigger threshold of brake deceleration for automatic stop of measurement
5. Trigger threshold of pedal force for automatic start of measurement
6. Trigger threshold of pedal force for automatic stop of measurement
7. Trigger threshold of tractive force for automatic start of measurement
8. Trigger threshold of tractive force for automatic stop of measurement
9. Trigger threshold of pressure 1 for automatic start of measurement
10. Trigger threshold of pressure 1 for automatic stop of measurement
11. Trigger threshold of pressure 2 for automatic start of measurement
12. Trigger threshold of pressure 2 for automatic stop of measurement
13. Trigger threshold of pressure 3 for automatic start of measurement
14. Trigger threshold of pressure 3 for automatic stop of measurement