47
Batch Processing Alarm
Press (*,3,3,) to turn on a special alarm condition. Press * to toggle between (AL STD) and (AL-BATCH).
If you are running using the BATCH key, and (AL-BATCH) is selected, then the ALARM will sound when a
batch is completed.
End Cycle Full
This flag for SPECIAL APPLICATIONS ONLY.
Press (*,4,4) to tell the controller to end a cycle when the weigh bin is FULL. Use the * key to toggle
between (END EMTY) or (END FULL).
Normal operation is to end the cycle EMPTY; (END EMTY). The (END FULL) option is only for special
installations where the sensor has been relocated BELOW the mix chamber and the instructions to do
otherwise.
Change Manual Mode Password
Press (*,4,5, followed by a 5 digit number) to change the PASSWORD number for entering the MANUAL
mode. The system is supplied with the number "11111" as the password number. If you wish to restrict
use of this mode to only yourself, you may make up your own number and enter it here.
WSD Systems Only – Change Weight Dispense Range
Special function - WSD DISPENSE systems only.
This function alters the range of requested dispense weights. 00.1 to 99.9 is standard. 001 to 999 is
optional using this function. Dispense systems are generally used for rotational molding.
Weigh Bin Double Dump
Press (*,5,2) to cause the weigh bin dump valve to operate two times. We call this a "double dump". If
you have problems with material hanging up in the weigh pan, this may help shake it loose.
Use the * key to toggle between (DBLD OFF) and (DBLD ON).
Press EXIT when done.
Cycle-by-Cycle Printout
Press (*,5,4) to set flag for a printout of data after each full dispense cycle. With this flag ON and with a
printer on line, four lines of information about the dispense cycle that just occurred will be sent to the
printer. This information includes dispense weight and percentage of each component, the internal rate
numbers used by the computer to determine dispense time, and the actual dispense time of each
component. This is excellent information to track the accuracy of each dispense cycle and the accuracy of
the entire system over an extended period of time. See: PRINTER OUTPUT for a more detailed
explanation.
Set Blender ID#
Press (*,6,6) to enter an identification number for this particular weigh scale blender. This I.D. number will
appear on all printed reports. If you have more than one unit, this helps to identify reports. If you are
using a computer to automatically gather data, then each controller must have a unique address. Valid
numbers are 000 to 255. When connected to a computer, do not use the number 000 for identification.
Special Applications Only – Additive Percent of Mix
Press (*,7,2) to change the Additive settings to be interpreted as percent of the entire MIX instead of
percent of the Natural. The display will say (APM -OFF). Press "*" to toggle flag to (APM -ON). (APM
stands for Additives Percent of Mix). This option has been added for a customer with a unique
requirement.
Leave this flag OFF, (APM- OFF), unless you have specific instructions to do otherwise.
CAUTION
: With this flag set, additive settings combined must NOT exceed 100 percent. From a practical
standpoint, they should not exceed 10 percent combined.