Section 2. Installation and Setup
13
**Did not encode properly. Try again.*07
--> Slide card right when ready -->
The 07 is the read-after-write status. The read status values are as follows:
Binary
Number Description
01
Error on Track 1
02
Error on Track 2
04
Error on Track 3
10
Blank Track 1
20 Blank
Track
2
40
Blank Track 3
The resulting value is the sum of these binary numbers; for example, 43 indicates that Track 3 is
blank (40) and errors were detected on Tracks 1 and 2 (01 + 02 =03). If Track 1 is blank and
Tracks 2 and 3 contain errors, the number is 16.
Setup - IntelliCoder
The IntelliCoder is configured in the factory prior to shipment. There are no setup options
required.
Refer to Section 4 for a description of the online operation.