37
SECTION 6. 4777 EMULATION MODE
This section contains information for the 4777 Emulation Mode.
INSTALLATION OF 4777 EMULATION MODE
The following equipment is required for installing the 4447 Emulation:
•
Model MT-95 RS-232 HiCo Encoder/Reader P/N 31010020
•
Power Cord P/N 71100001
•
HiCo and LoCo test cards (1 each)
•
Cable P/N 21015846 (MT-95 to IBM 4778 PIN-Pad)
Proceed as follows:
1.
Disconnect the system Y-cable from the 4777. Do not disconnect the Y-cable from the
IBM 4778 PIN-Pad.
2.
Connect Mag-Tek cable 21015846 to the rear panel of the MT-95, as shown in Figure
2-1.
3.
Connect the open end of the Y-cable to the open end of the Mag-Tek cable. The default
parameters are automatically configured.
4.
Plug the female end of the power cord into the rear panel of the encoder marked
“POWER”. Plug the other end into a power source.
5.
Press “
I
” on the switch marked “ON".
The MT-95 4777 Emulation mode will be preset at the Mag-Tek factory. If the encode energy
needs to be modified or the customer’s idle message needs to be changed, follow the instructions
below.
MT-95 SETUP FOR ENCODE ENERGY
1. Turn off power switch on MT-95.
2. Disconnect the communication cable.
3. Attach an AT-style keyboard.
4. Turn on the power switch.
The following will appear briefly on the LCD:
Содержание MT-95
Страница 7: ...vii...
Страница 8: ...viii Figure 1 1 MT 95 Encoder Reader...
Страница 12: ...MT 95 RS 232 HiCo LoCo Encoder Reader 4 Figure 1 2 Encoder Parts and Card Orientation...
Страница 22: ...MT 95 RS 232 HiCo LoCo Encoder Reader 14...
Страница 34: ...MT 95 RS 232 HiCo LoCo Encoder Reader 26...
Страница 44: ...MT 95 RS 232 HiCo LoCo Encoder Reader 36...
Страница 50: ...MT 95 RS 232 HiCo LoCo Encoder Reader 42...
Страница 52: ...MT 95 RS 232 HiCo LoCo Encoder Reader 44...