1.0 Introduction

Congratulations on your purchase! The MM Series remote control from

Magnum Energy, Inc. is designed to be simple to install and use, allow

easy control and quick indication of the inverter’s (and charger) status.

Remotes Available

The MM-R and the MM-RC are the two MM remote controls available to

use with the MM Series inverter. The appropriate remote to use

depends on whether your inverter includes the battery charger

feature. For MM Series inverters that do not have the battery charger,

the  MM-R is the recommended remote; for MM Series inverters that do

have the battery charger, the MM-RC is the recommended remote.
Depending on your inverter model, you can select one of the following

remotes:
MM-R - Provides three LED indicators for inverter status and includes a

remote ON/OFF switch; comes with 25’ cable. This remote is for MM

Series inverters without the battery charger feature; such as the

MM612 (requires serial number L1-201 or higher) or MM612G models.
MM-RC - Provides six LED indicators for inverter and charger status,

includes a remote ON/OFF switch; comes with 25’ cable. This remote is

for MM Series inverters with the battery charger feature; such as the

MM612AE, MM1212 or MM1212AE models.

Figure 1, MM Remotes

MM-R

MM-RC

BULK

ABSORB

FAULT

FLOAT

AC IN

INVERT

ON/OFF

INVERT

AC IN

FAULT

ON/OFF

1.0 Introduction

Basic Features

• Colored LED’s (Light Emitting Diodes) located on the front panel for

easy viewing of system status.

• RJ11 phone jack connection on remote for easy connection to

inverter.

• Status and information indicators used to determine system perfor-

mance and operating conditions including: inverter operation, charger

operation and any faults that occur.

• ON/OFF push-button for easy control of inverter and charger

operation.

• Easy installation and included mounting ring to give installers a

choice for mounting.

1

Содержание MM Series

Страница 1: ...Installation and Operation Guide Remote Controls for MM Series Inverters...

Страница 2: ...2006 Magnum Energy Inc...

Страница 3: ...y Inc 1111 80th Street SW Suite 250 Everett WA 98203 phone 425 353 8833 fax 425 353 8390 web www magnumenergy com Product Safety Instructions Read and follow all instructions and safety information co...

Страница 4: ...FF Switch 7 Monitoring the LED Indicators 8 MM R and MM RC Remotes 8 MM RC Remote Only 10 4 0 Warranty and Service Information 11 List of Figures Figure 1 MM Remotes 1 Figure 2 Communications Cable Co...

Страница 5: ...with 25 cable This remote is for MM Series inverters without the battery charger feature such as the MM612 requires serial number L1 201 or higher or MM612G models MM RC Provides six LED indicators fo...

Страница 6: ...ted place Plan the cable route from the remote to the inverter to ensure there are no obstructions that can t be overcome before you do any cutting or drilling Allow ample room to access the ON OFF sw...

Страница 7: ...dimensions DO NOT cut the opening too big to ensure there are no cracks around the display and that there is enough material for the screws to secure the display Remove any wall insulation if applicab...

Страница 8: ...d cut break the appropriate tab on the mounting ring 4 Pull the cable through the mounting ring and place the ring with the removed tab over the communication cable against the wall 5 Position the mou...

Страница 9: ...2006 Magnum Energy Inc Figure 5 Remote Display Dimensions Figure 6 Mounting Ring Dimensions 2 0 Installation 5 BULK ABSORB FLOAT INVERT AC IN FAULT ON OFF Side Front Side Front...

Страница 10: ...a tion Guide to help clear the fault condition Factory Default Settings Your MM Series inverter has many functions that have changeable settings These settings are preset and loaded by the inverter wh...

Страница 11: ...battery charger feature this switch can also be used to disable the charger Charger Standby so that all the incoming power can be used exclusively for the AC loads To turn the charger off press and h...

Страница 12: ...energy from the battery to supply AC power to the loads connected to the inverter and AC IN LED indicator is On solid The inverter is in Standby The external AC power Utility or generator connected to...

Страница 13: ...s Over temperature condition The internal temperature of the inverter has risen above acceptable limits caused by loads too great for the inverter to operate continuously or by lack of ventilation to...

Страница 14: ...arger reduces the charge rate to maintain temperature or 2 The AC input voltage has fallen below 85 VAC the charger reduces the charge rate to help stabilize the incoming AC voltage Off charger is not...

Страница 15: ...ir determined by the price paid by the original purchaser Magnum Energy shall not be liable for any other losses or damages 4 Upon request from Magnum Energy the original purchaser must prove the prod...

Страница 16: ...2006 Magnum Energy Inc Magnum Energy Inc 1111 80th Street SW Suite 250 Everett WA 98203 phone 425 353 8833 fax 425 353 8390 web www magnumenergy com PN 64 00012...

Отзывы: