2006 Magnum Energy Inc

.

Disclaimer of Liability

Since the use of this manual and the conditions or methods of

installation, operation, use and maintenance of the MM Series Remote

Control are beyond the control of Magnum Energy Inc., this company

does not assume responsibility and expressly disclaims liability for

loss, damage or expense, whether direct, indirect, consequential or

incidental, arising out of or anyway connected with such installation,

operation, use, or maintenance.
Due to continuous improvements and product updates, the images

shown in this manual may not exactly match the unit purchased.

Restrictions on Use

The MM Series Remote Control shall not be used in connection with

life support systems, life saving or other medical equipment or

devices. Use of this particular equipment is at your own risk.

Contact Information

Magnum Energy, Inc.

1111 80th Street SW - Suite 250

Everett, WA 98203

phone: 425.353.8833

fax: 425.353.8390

web: www.magnumenergy.com

Product Safety Instructions

Read and follow all instructions and safety information contained in this

manual before installing or using this product.
• All electrical work must be performed in accordance with local, state

and federal electrical codes.
• This product is designed for indoor / compartment installation. It

must not be exposed to rain, snow, moisture or liquids of any type.
• Use insulated tools to reduce the chance of electrical shock or

accidental short circuits.
• Always verify proper wiring prior to connecting the remote.

Safety Symbols
To reduce the risk of electrical shock, fire, or other safety hazard, the

following safety symbols have been placed throughout this manual to

indicate dangerous and important safety instructions.

Warning - Indicates a dangerous voltage or condition exists.

Caution - Indicates a critical step necessary for the safe

installation and operation of the unit.

Note - Indicates an important statement.

i

Содержание MM Series

Страница 1: ...Installation and Operation Guide Remote Controls for MM Series Inverters...

Страница 2: ...2006 Magnum Energy Inc...

Страница 3: ...y Inc 1111 80th Street SW Suite 250 Everett WA 98203 phone 425 353 8833 fax 425 353 8390 web www magnumenergy com Product Safety Instructions Read and follow all instructions and safety information co...

Страница 4: ...FF Switch 7 Monitoring the LED Indicators 8 MM R and MM RC Remotes 8 MM RC Remote Only 10 4 0 Warranty and Service Information 11 List of Figures Figure 1 MM Remotes 1 Figure 2 Communications Cable Co...

Страница 5: ...with 25 cable This remote is for MM Series inverters without the battery charger feature such as the MM612 requires serial number L1 201 or higher or MM612G models MM RC Provides six LED indicators fo...

Страница 6: ...ted place Plan the cable route from the remote to the inverter to ensure there are no obstructions that can t be overcome before you do any cutting or drilling Allow ample room to access the ON OFF sw...

Страница 7: ...dimensions DO NOT cut the opening too big to ensure there are no cracks around the display and that there is enough material for the screws to secure the display Remove any wall insulation if applicab...

Страница 8: ...d cut break the appropriate tab on the mounting ring 4 Pull the cable through the mounting ring and place the ring with the removed tab over the communication cable against the wall 5 Position the mou...

Страница 9: ...2006 Magnum Energy Inc Figure 5 Remote Display Dimensions Figure 6 Mounting Ring Dimensions 2 0 Installation 5 BULK ABSORB FLOAT INVERT AC IN FAULT ON OFF Side Front Side Front...

Страница 10: ...a tion Guide to help clear the fault condition Factory Default Settings Your MM Series inverter has many functions that have changeable settings These settings are preset and loaded by the inverter wh...

Страница 11: ...battery charger feature this switch can also be used to disable the charger Charger Standby so that all the incoming power can be used exclusively for the AC loads To turn the charger off press and h...

Страница 12: ...energy from the battery to supply AC power to the loads connected to the inverter and AC IN LED indicator is On solid The inverter is in Standby The external AC power Utility or generator connected to...

Страница 13: ...s Over temperature condition The internal temperature of the inverter has risen above acceptable limits caused by loads too great for the inverter to operate continuously or by lack of ventilation to...

Страница 14: ...arger reduces the charge rate to maintain temperature or 2 The AC input voltage has fallen below 85 VAC the charger reduces the charge rate to help stabilize the incoming AC voltage Off charger is not...

Страница 15: ...ir determined by the price paid by the original purchaser Magnum Energy shall not be liable for any other losses or damages 4 Upon request from Magnum Energy the original purchaser must prove the prod...

Страница 16: ...2006 Magnum Energy Inc Magnum Energy Inc 1111 80th Street SW Suite 250 Everett WA 98203 phone 425 353 8833 fax 425 353 8390 web www magnumenergy com PN 64 00012...

Отзывы: