3.0 Operation
3.0 Operation
Start-up
After Installing and connecting the MM Series remote control, the
remote should be tested to ensure it is functional.
1. Press the ON/OFF push-button located on the display panel.
Note: The ON/OFF control switch is a push-button switch which
functions by momentary pressing and releasing.
2. After pressing the ON/OFF switch, verify the INVERT indicator
(green LED) is on (solid or blinking) and the status indicator on the
MM Series inverter is also on.
3. Press the ON/OFF switch again to turn the inverter off and verify
the INVERT indicator on the remote and the status indicator on the
inverter both go off.
If the remote passes all the steps, the inverter is ready for use.
If the remote fails any of the steps fails, check all the connections at
both ends of the communications cable and ensure the inverter is
operational. If the FAULT indicator comes on, refer to the Trouble-
shooting section in the MM Series Inverters, Installation and Opera-
tion Guide to help clear the fault condition.
Factory Default Settings
Your MM Series inverter has many functions that have changeable
settings. These settings are preset and loaded by the inverter when
turned on. However, if the MM remote control is connected to the
inverter, the settings from the remote over-ride any default settings
in the inverter. The settings in the remote are saved in the remote’s
non-volatile memory and will be used - even if DC power to the
inverter is lost - as long as the remote is connected. See Table 1 for
the inverter’s default settings and the settings that are changed when
connected to the MM remote.
Function
Inverter Settings
Remote Settings
Search Watts
NA (MM612 / MM612G),
5W (all other MM Series)
NA (MM612 / MM612G),
5W (all other MM Series)
LowBatCutOut
10.0 VDC
10.0 VDC
400 AmpHrs
400 AmpHrs
(Absorb Time = 120 minutes)
(Absorb Time = 120 minutes)
Flooded - Liquid Lead Acid
Flooded - Liquid Lead Acid
(Bulk = 14.6 VDC,
(Bulk = 14.6 VDC,
Float = 13.4 VDC)
Float = 13.4 VDC)
Charge Rate
100%
100%
VAC dropout
80VAC
90VAC
Battery AmpHrs
Battery Type
Table 1, Inverter and Remote Settings
Note: For more information on these settings, refer to the MM
Series Inverters, Installation and Operation Guide.