background image

©

2006 Magnum Energy Inc

.

ON/OFF Switch

The ON/OFF Switch is a momentary push-button switch that duplicates

the ON/OFF switch on the inverter. This switch also allows additional

changes to be made while in the Invert or Charge Mode.
When the inverter is first connected to the batteries, the inverter and

remote go through an internal 10 seconds start-up test. After this test

is completed, the ON/OFF switch can be pressed to turn on the

inverter. Once the inverter has been turned on, momentarily pressing

the ON/OFF switch alternately turns the inverter On/Standby and Off.
On models with the search mode function, the ON/OFF switch can be

used to enable or disable the search mode. While in the INVERT

Mode, pressing and holding this switch for three seconds will allow the

search mode to alternate between Disabled (Inverter always on -

indicated by the INVERT LED always on) and 5W (the inverter is

looking for at least a 5 watt load to turn on and start inverting -

indicated by the INVERT LED Blinking once a second).
On models with the battery charger feature, this switch can also be

used to disable the charger (Charger Standby) so that all the

incoming power can be used exclusively for the AC loads. To turn the

charger off, press and hold the ON/OFF switch for three seconds (you

must be in the Charge Mode). When this happens, the charging

indicators (BULK, ABSORB and FLOAT) will go off. To turn the charger

back on, press and hold the ON/OFF switch for three seconds again.

When the charger is again enabled, one of the charging indicators will

come on to show the current charge stage.

Warning - When any external AC power is passing through

the inverter and present on the output. Pressing the ON/OFF

switch will not remove this AC power on the inverter’s output.

INVERT

(green LED)

ON/OFF

AC IN

(green LED)

FAULT

(red LED)

ON/OFF 

Switch

BULK

(yellow LED)

ABSORB

 (yellow LED)

FLOAT

(green LED)

Figure 7, LED Indicators and ON/OFF Switch

Operation

The 

MM Series remote controls 

have an ON/OFF switch that performs

the sa

me function as the ON/OFF switch on the front of the MM Series

inverter. This remote control also has LED indicators to show the

current operating mode of the inverter and charger (MM-RC only) and

to help troubleshoot you system if you have a fault.

7

3.0 Operation

Содержание MM Series

Страница 1: ...Installation and Operation Guide Remote Controls for MM Series Inverters...

Страница 2: ...2006 Magnum Energy Inc...

Страница 3: ...y Inc 1111 80th Street SW Suite 250 Everett WA 98203 phone 425 353 8833 fax 425 353 8390 web www magnumenergy com Product Safety Instructions Read and follow all instructions and safety information co...

Страница 4: ...FF Switch 7 Monitoring the LED Indicators 8 MM R and MM RC Remotes 8 MM RC Remote Only 10 4 0 Warranty and Service Information 11 List of Figures Figure 1 MM Remotes 1 Figure 2 Communications Cable Co...

Страница 5: ...with 25 cable This remote is for MM Series inverters without the battery charger feature such as the MM612 requires serial number L1 201 or higher or MM612G models MM RC Provides six LED indicators fo...

Страница 6: ...ted place Plan the cable route from the remote to the inverter to ensure there are no obstructions that can t be overcome before you do any cutting or drilling Allow ample room to access the ON OFF sw...

Страница 7: ...dimensions DO NOT cut the opening too big to ensure there are no cracks around the display and that there is enough material for the screws to secure the display Remove any wall insulation if applicab...

Страница 8: ...d cut break the appropriate tab on the mounting ring 4 Pull the cable through the mounting ring and place the ring with the removed tab over the communication cable against the wall 5 Position the mou...

Страница 9: ...2006 Magnum Energy Inc Figure 5 Remote Display Dimensions Figure 6 Mounting Ring Dimensions 2 0 Installation 5 BULK ABSORB FLOAT INVERT AC IN FAULT ON OFF Side Front Side Front...

Страница 10: ...a tion Guide to help clear the fault condition Factory Default Settings Your MM Series inverter has many functions that have changeable settings These settings are preset and loaded by the inverter wh...

Страница 11: ...battery charger feature this switch can also be used to disable the charger Charger Standby so that all the incoming power can be used exclusively for the AC loads To turn the charger off press and h...

Страница 12: ...energy from the battery to supply AC power to the loads connected to the inverter and AC IN LED indicator is On solid The inverter is in Standby The external AC power Utility or generator connected to...

Страница 13: ...s Over temperature condition The internal temperature of the inverter has risen above acceptable limits caused by loads too great for the inverter to operate continuously or by lack of ventilation to...

Страница 14: ...arger reduces the charge rate to maintain temperature or 2 The AC input voltage has fallen below 85 VAC the charger reduces the charge rate to help stabilize the incoming AC voltage Off charger is not...

Страница 15: ...ir determined by the price paid by the original purchaser Magnum Energy shall not be liable for any other losses or damages 4 Upon request from Magnum Energy the original purchaser must prove the prod...

Страница 16: ...2006 Magnum Energy Inc Magnum Energy Inc 1111 80th Street SW Suite 250 Everett WA 98203 phone 425 353 8833 fax 425 353 8390 web www magnumenergy com PN 64 00012...

Отзывы: