IMPULSE•VG+ Series 3 Instruction Manual – 07/25/05
5-33
Table 5-3: G5IN4 Digital Multi-Function Input Sets (0 through F)
Multi-Function Input Assigned to Each Terminal
First Digit (From
Left) You Enter
Terminal 1
Terminal 2
Terminal 3
Terminal 4
0
No function
No function
No function
No function
1
Upper Limit–SLOW
DOWN; Normally Closed
Upper Limit–STOP;
Normally Closed
Lower Limit–SLOW
DOWN; Normally Closed
Lower Limit–STOP;
Normally Closed
2
Upper Limit–SLOW
DOWN; Normally Open
Upper Limit–STOP;
Normally Open
Lower Limit–SLOW
DOWN; Normally Open
Lower Limit–STOP;
Normally Open
3*
Multi-Step Speed 2
Multi-Step Speed 3
Multi-Step Speed 4
Multi-Step Speed 5
4*
Hold function (2nd step of
Three-Step Infinitely
Variable).
Acceleration function (2nd
step of Two-Step Infinitely
Variable or 3rd step of
Three-Step Infinitely
Variable).
Micro-Positioning Control
Multiplier 1
Upper Limit–STOP;
Normally Closed
5
Upper Limit–STOP
Normally Closed
Upper Limit–SLOW
DOWN; Normally Closed
Lower Limit–STOP;
Normally Closed
Lower Limit–SLOW
DOWN; Normally Closed
6
Upper Limit–STOP;
Normally Open
Upper Limit–SLOW
DOWN; Normally Open
Lower Limit–STOP;
Normally Open
Lower Limit–SLOW
DOWN; Normally Open
7*
Multi-Step Speed 5
Multi-Step Speed 4
Multi-Step Speed 3
Multi-Step Speed 2
8*
Upper Limit–STOP;
Normally Closed
Micro-Positioning Control
Multiplier 1
Acceleration function (2nd
step or Two-Step Infinitely
Variable or 3rd step of
Three-Step Infinitely
Variable).
Hold function (2nd step of
Three-Step Infinitely
Variable).
9
Upper Limit–STOP;
Normally Closed
Lower Limit–STOP;
Normally Closed
Micro-Positioning Control
Multiplier 1
External base block N/O
A
Upper Limit–STOP;
Normally Closed
Lower Limit–STOP;
Normally Closed
Micro-Positioning Control
Multiplier 1
Weight Measurement
Control
B
Ultra-Lift Enable
Brake answerback
Micro-Positioning Control
Multiplier 1
Micro-Positioning Control
Multiplier 2
C
External Base Block N/O
Phantom Fault N/O
Klixon N/O
BE6 Up Speed Limit
D
External Base Block N/O
Brake Answerback
Micro-Positioning Control
Multiplier 1
Micro-Positioning Control
Multiplier 2
E
Alternate Upper Limit
Frequency Reference
Option/Inverter Run and
Speed Reference
Changeover
Micro-Positioning Control
Multiplier 1
Brake Answerback
F
External Base Block N/C
Phantom Fault N/C
Klixon N/C
BE6 Up Speed Limit
* If using the G5IN4 to input speed references, A1-04 should be set for Data 7 (G5IN4 Opt Card). This will help to avoid and OPE03
fault caused by having more than one terminal programmed with the same data.
Содержание IMPULSE VG+ Series 3
Страница 1: ...Software 8001 X July 2005 Part Number 140 10257 Copyright 2005 Magnetek Instruction Manual...
Страница 6: ...c h a p t e r 1 Introduction...
Страница 7: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 1 2 This page intentionally left blank...
Страница 14: ...c h a p t e r 2 Installation...
Страница 15: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 2 2 This page intentionally left blank...
Страница 23: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 2 10 This page intentionally left blank...
Страница 24: ...c h a p t e r 3 Wiring...
Страница 25: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 3 2 This page intentionally left blank...
Страница 40: ...c h a p t e r 4 Programming Basic Features...
Страница 41: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 4 2 This page intentionally left blank...
Страница 54: ...c h a p t e r 5 Programming Advanced Features...
Страница 55: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 5 2 This page intentionally left blank...
Страница 149: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 5 96...
Страница 150: ...Troubleshooting IMPULSE VG Series 3 c h a p t e r 6...
Страница 151: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 6 2 This page intentionally left blank...
Страница 170: ...A p p e n d i x A IMPULSE VG Series 3 Parameter Listing...
Страница 171: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 A 2 This page intentionally left blank...
Страница 183: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 A 14...